High-density surface electromyography improves the identification of oscillatory synaptic inputs to motoneurons.

نویسندگان

  • Chiel van de Steeg
  • Andreas Daffertshofer
  • Dick F Stegeman
  • Tjeerd W Boonstra
چکیده

Many studies have addressed corticomuscular coherence (CMC), but broad applications are limited by low coherence values and the variability across subjects and recordings. Here, we investigated how the use of high-density surface electromyography (HDsEMG) can improve the detection of CMC. Sixteen healthy subjects performed isometric contractions at six low-force levels using a pinch-grip, while HDsEMG of the adductor pollicis transversus and flexor and abductor pollicis brevis and whole-head magnetoencephalography were recorded. Different configurations were constructed from the HDsEMG grid, such as a bipolar and Laplacian montage, as well as a montage based on principal component analysis (PCA). CMC was estimated for each configuration, and the strength of coherence was compared across configurations. As expected, performance of the precision-grip task resulted in significant CMC in the β-frequency band (16-26 Hz). Compared with a bipolar EMG montage, all multichannel configurations obtained from the HDsEMG grid revealed a significant increase in CMC. The configuration, based on PCA, showed the largest (37%) increase. HDsEMG did not reduce the between-subject variability; rather, many configurations showed an increased coefficient of variation. Increased CMC presumably reflects the ability of HDsEMG to counteract inherent EMG signal factors-such as amplitude cancellation-which impact the detection of oscillatory inputs. In contrast, the between-subject variability of CMC most likely has a cortical origin.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delayed Synaptic Changes in Axotomized Spinal Motoneurons of Newborn Rats Associated with Progressive Neuronal Loss: Immunohistochemical, Ultrastructural, and Quantitative Study

Background and Objective: Sciatic nerve transection is characterized by a rapid wave of motoneuron death associated with progressive synaptic lesions. The purpose of this study was to evaluate the long term synaptic changes. Materials and Methods: This basic study was carried out on paraffin- or resin-em...

متن کامل

Physiological changes accompanying anatomical remodeling of mammalian motoneurons during postnatal development.

The development of respiratory motoneurons provides unique data that may be generalized to other mammalian motoneuron populations. Like other motoneurons, respiratory motoneurons undergo developmental changes in the shape of the action potential and their repetitive firing. The unique observations concern the postnatal change in the recruitment pattern of cat phrenic motoneurons that is correla...

متن کامل

A gradient in endogenous rhythmicity and oscillatory drive matches recruitment order in an axial motor pool.

The rhythmic firing behavior of spinal motoneurons is a function of their electrical properties and synaptic inputs. However, the relative contribution of endogenous versus network-based rhythmogenic mechanisms to locomotion is unclear. To address this issue, we have recorded from identified motoneurons and compared their current-evoked firing patterns to network-driven ones in the larval zebra...

متن کامل

Time Course of Axotomy-induced Changes in Synaptophysin Pattern and Synaptic Reaction of Spinal Motoneurons in Adult Rat

Background and Objective: Evaluation of degenerative changes of motoneurons and their related synapses can be useful in understanding the mechanisms of neurodegenerative diseases and their potential treatment. The present electron microscopic and immunohistochemical study investigates the axotomy-induced...

متن کامل

Spike-firing resonance in hypoglossal motoneurons.

During an inspiration the output of hypoglossal (XII) motoneurons (HMs) in vitro is characterized by synchronous oscillatory firing in the 20- to 40-Hz range. To maintain synchronicity it is important that the cells fire with high reliability and precision. It is not known whether the intrinsic properties of HMs are tuned to maintain synchronicity when stimulated with time-varying inputs. We in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 116 10  شماره 

صفحات  -

تاریخ انتشار 2014