Optical saturation measurements of fluorophores in solution with pulsed femtosecond excitation and two-dimensional CCD camera detection.
نویسندگان
چکیده
We present a new method for the measurement of saturation of the optical transition of fluorescent molecules in solution, which is based on detection with a CCD camera of a two-dimensional projection of the three-dimensional, spatially nonuniform fluorescence intensity distribution as generated in a bulk solution of the fluorophore by excitation with focused femtosecond optical pulses. Essential to the method is (a) a combination of information from a measurement in saturation and one not in saturation and (b) for the measurement in saturation, the simultaneous observation of both saturated and nonsaturated regions of the fluorescence intensity distribution. The experimental setup is straightforward and good agreement is found between the theory and the experimental data.
منابع مشابه
Multiphoton excitation cross-sections of molecular fluorophores
Nonlinear excitation of fluorophores through molecular absorption of two or three near-infra-red photons from the tightly focused femtosecond pulses of a mode-locked laser offers the cellular biologist an unprecedented panoply of biomolecular indicators for microscopic imaging and cellular analysis. Measurements of the two-photon excitation spectra of 25 ultra-violet and visible absorbing fluor...
متن کاملSingle-atom-sensitive fluorescence imaging of ultracold quantum gases
We present a novel imaging system for ultracold quantum gases in expansion. After release from a confining potential, atoms fall through a sheet of resonant excitation laser light and the emitted fluorescence photons are imaged onto an amplified CCD camera using a high numerical aperture optical system. The imaging system reaches an extraordinary dynamic range, not attainable with conventional ...
متن کاملSingle-particle-sensitive imaging of freely propagating ultracold atoms
We present a novel imaging system for ultracold quantum gases in expansion. After release from a confining potential, atoms fall through a sheet of resonant excitation laser light and the emitted fluorescence photons are imaged onto an amplified CCD camera using a high numerical aperture optical system. The imaging system reaches an extraordinary dynamic range, not attainable with conventional ...
متن کاملFluorescence light suppression in Raman Spectroscopy using ultrafast time gated CCD camera
A high level of fluorescence background signal rejection was achieved for solid and powder samples by using a combination of simple low-resolution spectrograph and ultrafast intensified/gated CCD camera. The unique timing characteristics of CCD camera match exceptionally well characteristics of Ti:sapphire oscillator allowing fast gated light detection at a repetition rate of up to 110 MHz, mak...
متن کاملThe perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs
Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 36 18 شماره
صفحات -
تاریخ انتشار 1997