Nuclear-weighted X-ray maximum entropy method - NXMEM.

نویسندگان

  • Sebastian Christensen
  • Niels Bindzus
  • Mogens Christensen
  • Bo Brummerstedt Iversen
چکیده

Subtle structural features such as disorder and anharmonic motion may be accurately characterized from nuclear density distributions (NDDs). As a viable alternative to neutron diffraction, this paper introduces a new approach named the nuclear-weighted X-ray maximum entropy method (NXMEM) for reconstructing pseudo NDDs. It calculates an electron-weighted nuclear density distribution (eNDD), exploiting that X-ray diffraction delivers data of superior quality, requires smaller sample volumes and has higher availability. NXMEM is tested on two widely different systems: PbTe and Ba(8)Ga(16)Sn(30). The first compound, PbTe, possesses a deceptively simple crystal structure on the macroscopic level that is unable to account for its excellent thermoelectric properties. The key mechanism involves local distortions, and the capability of NXMEM to probe this intriguing feature is established with simulated powder diffraction data. In the second compound, Ba(8)Ga(16)Sn(30), disorder among the Ba guest atoms is analysed with both experimental and simulated single-crystal diffraction data. In all cases, NXMEM outperforms the maximum entropy method by substantially enhancing the nuclear resolution. The induced improvements correlate with the amount of available data, rendering NXMEM especially powerful for powder and low-resolution single-crystal diffraction. The NXMEM procedure can be implemented in existing software and facilitates widespread characterization of disorder in functional materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carrier concentration dependence of structural disorder in thermoelectric Sn1−xTe

SnTe is a promising thermoelectric and topological insulator material. Here, the presumably simple rock salt crystal structure of SnTe is studied comprehensively by means of high-resolution synchrotron single-crystal and powder X-ray diffraction from 20 to 800 K. Two samples with different carrier concentrations (sample A = high, sample B = low) have remarkably different atomic displacement par...

متن کامل

Critical Analysis of Non-Nuclear Electron-Density Maxima and the Maximum Entropy Method.

Experimental evidence for the existence of non-nuclear maxima in charge densities is questioned. It is shown that the non-nuclear maxima reported for silicon are artifacts of the maximum entropy method that was used to analyze the x-ray diffraction data. This method can be improved by the use of appropriate prior information. We report systematic tests of the improved method leading to the abse...

متن کامل

Bayesian inversion method for 3D dental X-ray imaging

Diagnostic and operational tasks in dentistry require three-dimensional (3D) information about tissue. A novel type of low dose dental 3D X-ray imaging is considered. Given projection images taken from a few sparsely distributed directions using the dentist’s regular X-ray equipment, the 3D X-ray attenuation function is reconstructed. This is an ill-posed inverse problem, and Bayesian inversion...

متن کامل

Imagi,ng of Diffraction Data by the Maximum Entropy Method -anew Approach to Crystallography-

The recent works of the Maximum Entropy Method (MEM) in the field of accurate crystal structure analysis were reviewed, The role of MEM analysis in these works are described by the concept of Imaging of Diffraction Data (IDD). Assuming that the phase problem is solved by direct method or some other way, it is possible to construct the real space image, such as the electron density distribution ...

متن کامل

Bayesian Restoration of Medical X-Ray Digital Images

Image entropy as prior in Bayesian inference was applied to the restoration of X-ray digital images with additive zero mean Gaussian distributed noise. An iterative algorithm based on a conjugate gradient method with numerical evaluation of partial derivatives was developed to efficiently minimize the potential function associated to any positive, additive distribution. The correlation matrix o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta crystallographica. Section A, Foundations and advances

دوره 71 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2015