Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial.
نویسندگان
چکیده
BACKGROUND There are no reports on a large-scale randomized trial exploring optimal dual antiplatelet therapy (DAPT) duration after biodegradable polymer sirolimus-eluting stent implantation. We sought to report the outcomes of a randomized substudy of the prospective Evaluate Safety and Effectiveness of the Tivoli DES and the Firebird DES for Treatment of Coronary Revascularization (I-LOVE-IT 2) trial. METHODS AND RESULTS In the prospective noninferiority randomized I-LOVE-IT 2 trial, 1829 patients allocated to the biodegradable polymer sirolimus-eluting stent group were also randomized to receive either 6-month (n=909) or 12-month DAPT (n=920). The primary end points of this noninferiority substudy were 12-month target lesion failure (composite of cardiac death, target vessel myocardial infarction or clinically indicated target lesion revascularization), and the major secondary end points were 12-month net adverse clinical and cerebral events (composite of all-cause death, all myocardial infarction, stroke, or major bleeding [Bleeding Academic Research Consortium type ≥3]). The 12-month target lesion failure in 6-month DAPT group was comparable with the 12-month DAPT group (6.8% versus 5.9%; difference and 95% confidence interval, 0.87% [-1.37% to 3.11%], P for noninferiority=0.0065). Further follow-up at 18 months showed that incidence of target lesion failure and net adverse clinical and cerebral events were similar between the 2 groups (7.5% versus 6.3%, log-rank P=0.32; 7.8% versus 7.3%, log-rank P=0.60; respectively), as well as their individual end point components. CONCLUSIONS This study indicated noninferiority in safety and efficacy of 6-month versus 12-month DAPT after implantation of a novel biodegradable polymer sirolimus-eluting stent. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01681381.
منابع مشابه
Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent
متن کامل
Dual Antiplatelet Therapy Over 6 Months Increases the Risk of Bleeding after Biodegradable Polymer-Coated Sirolimus Eluting Stents Implantation: Insights from the CREATE Study
BACKGROUND The optimal duration of dual antiplatelet therapy (DAPT) after drug-eluting stent (DES) implantation remains controversial. The primary aim of our study was to evaluate the impact of optimal DAPT duration on bleeding events between 6 and 12 months after biodegradable polymer-coated DES implantation. The secondary aim is to determine the predictors and prognostic implications of bleed...
متن کاملEfficacy and safety of 12 versus 48 months of dual antiplatelet therapy after implantation of a drug-eluting stent: the OPTImal DUAL antiplatelet therapy (OPTIDUAL) trial: study protocol for a randomized controlled trial
BACKGROUND Dual antiplatelet therapy with aspirin and thienopyridine is required after placement of coronary drug-eluting stents (DES) to prevent thrombotic complications. Current clinical guidelines recommend at least 6 to 12 months of treatment after a DES implantation, but it may be beneficial to apply dual antiplatelet therapy for a longer duration. METHODS/DESIGN The optimal dual antipla...
متن کامل2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.
OBJECTIVES This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. BACKGROUND BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegrada...
متن کاملUltrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial.
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2016