Pupil-segmentation-based adaptive optical correction of a high-numerical-aperture gradient refractive index lens for two-photon fluorescence endoscopy.

نویسندگان

  • Chen Wang
  • Na Ji
چکیده

The intrinsic aberrations of high-NA gradient refractive index (GRIN) lenses limit their image quality as well as field of view. Here we used a pupil-segmentation-based adaptive optical approach to correct the inherent aberrations in a two-photon fluorescence endoscope utilizing a 0.8 NA GRIN lens. By correcting the field-dependent aberrations, we recovered diffraction-limited performance across a large imaging field. The consequent improvements in imaging signal and resolution allowed us to detect fine structures that were otherwise invisible inside mouse brain slices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of nonlinear optical properties of Carbon nanotubes synthesized by Nickel and Nickel-Cobalt catalysts using Z-scan technique

The nonlinear optical properties of carbon nanotubes (CNTs) have been studied by using the Z-scan technique. Experiments are performed by CW second harmonic of Nd-YAG laser at 532 nm wavelength with a power of 40 mW. The samples are synthesized by the chemical vapor deposition (CVD) method in the presence of Nickel and Nickel-Cobalt catalysts. In this work, for the first time, effect of the typ...

متن کامل

Pupil-segmentation-based adaptive optical microscopy with full-pupil illumination.

Optical aberrations deteriorate the performance of microscopes. Adaptive optics can be used to improve imaging performance via wavefront shaping. Here, we demonstrate a pupil-segmentation based adaptive optical approach with full-pupil illumination. When implemented in a two-photon fluorescence microscope, it recovers diffraction-limited performance and improves imaging signal and resolution.

متن کامل

Three-photon excited fluorescence imaging of unstained tissue using a GRIN lens endoscope

We present a compact and portable three-photon gradient index (GRIN) lens endoscope system suitable for imaging of unstained tissues, potentially deep within the body, using a GRIN lens system of 1 mm diameter and 8 cm length. The lateral and axial resolution in water is 1.0 μm and 9.5 μm, respectively. The ~200 μm diameter field of view is imaged at 2 frames/s using a fiber-based excitation so...

متن کامل

Correcting spherical aberrations in a biospecimen using a transmissive liquid crystal device in two-photon excitation laser scanning microscopy.

Two-photon excitation laser scanning microscopy has enabled the visualization of deep regions in a biospecimen. However, refractive-index mismatches in the optical path cause spherical aberrations that degrade spatial resolution and the fluorescence signal, especially during observation at deeper regions. Recently, we developed transmissive liquid-crystal devices for correcting spherical aberra...

متن کامل

اندازه‌گیری ضرایب نوری غیرخطی شیشه‌های چلکاجنید به روش جاروب- z و روش ترکیب چهار موج تبگهن DFWM

Chalcogenide glasses such as arseic sulfide(As2 S3 ) have attracted attention for applications such as all-optical switching in high speed communication. This is due to their high non-linear refractive-index. Z-scan and the Degenerate four wave mixing (DFWM) techniques can be used to measure the non-linear refractive index n 2 and the two photon absorption coefficient β . A simaltanous closed-a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics letters

دوره 37 11  شماره 

صفحات  -

تاریخ انتشار 2012