Study on Permanent Magnet Synchronous Demagnetization Fault Performance

نویسندگان

  • Zhiyan ZHANG
  • Cunxiang YANG
  • Duanlei YUAN
چکیده

The relationship of permanent magnetic material characteristic parameters was analyzed, and a simulation method of a permanent magnet synchronous motor (PMSM) rotor demagnetization fault was put forward. Based on this, a simulation model of the PMSM under partial demagnetization and uniform demagnetization fault were established, and different degrees demagnetization fault was simulated. Relationship between output torque and initial phase was gained by applying different initial angle current excitation source in order to establish the reasonable simulation model. Simulation results show that magnetic field strength and output torque get smaller and smaller with increasingly fault severity. The magnetic field asymmetry of PMSM partial demagnetization is more and more serious with increasingly fault severity, and the magnetic field scale of PMSM uniform demagnetization decreased significantly. The harmonic analyses using Fast Fourier Transform (FFT) show that the fault diagnosis method based on the harmonic wave analysis is only suitable for partial demagnetization fault of the PMSM, and not apply to uniform demagnetization fault of the PMSM. Copyright © 2014 IFSA Publishing, S. L.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Permanent Magnet Demagnetization in Synchronous Machines during Multiple Short-Circuit Fault Conditions

Faults in electrical machines can vary in severity and affect different parts of the machine. This study focuses on various kinds of short-circuits on the terminal side of a generic 20 kW surface mounted permanent magnet synchronous generator and how successive faults affect the performance of the machine. The study was conducted with the commercially available finite element method software CO...

متن کامل

Investigation of Demagnetization Effect in an Interior V-Shaped Magnet Synchronous Motor at Dynamic and Static Conditions

Permanent magnet motors have been considered for a variety of applications due to their features such as high power density and high efficiency. One of the issues that should be investigated in the design of these motors is the demagnetization problem. Usually, the demagnetization analysis is carried out in a steady state, while demagnetization effect in dynamic condition is more considerable d...

متن کامل

Online Fault Detection of Permanent Magnet Demagnetization for IPMSMs by Nonsingular Fast Terminal-Sliding-Mode Observer

To prevent irreversible demagnetization of a permanent magnet (PM) for interior permanent magnet synchronous motors (IPMSMs) by flux-weakening control, a robust PM flux-linkage nonsingular fast terminal-sliding-mode observer (NFTSMO) is proposed to detect demagnetization faults. First, the IPMSM mathematical model of demagnetization is presented. Second, the construction of the NFTSMO to estima...

متن کامل

Harmonic Analysis and Fault-Tolerant Capability of a Semi-12-Phase Permanent-Magnet Synchronous Machine Used for EVs

This paper deals with a fault-tolerant semi-12-phase permanent-magnet synchronous machine (PMSM) used for electric vehicles. High fault-tolerant and low toque ripple features are achieved by employing fractional slot concentrated windings (FSCWs) and open windings. Excessive magnetomotive force (MMF) harmonic components can lead to thermal demagnetization of rotor magnets as well as high core l...

متن کامل

Starting Characteristic Analysis of LSPM for Pumping System Considering Demagnetization

This paper presents the design process of a high performance 3-phase 3.7 kW 2-pole line start permanent magnet synchronous motor for pumping system. A method was proposed to study the starting torque characteristics considering line start with high inertia load. A d-q model including cage was built to study the synchronization capability. Time-stepping finite element method analysis was utilize...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014