Temperature-controlled in vivo ocular exposure to 1090-nm radiation suggests that near-infrared radiation cataract is thermally induced.
نویسندگان
چکیده
The damage mechanism for near-infrared radiation (IRR) induced cataract is unclear. Both a photochemical and a thermal mechanism were suggested. The current paper aims to elucidate a photochemical effect based on investigation of irradiance-exposure time reciprocity. Groups of 20 rats were unilaterally exposed to 96-W/cm(2) IRR at 1090 nm within the dilated pupil accumulating 57, 103, 198, and 344 kJ/cm(2), respectively. Temperature was recorded at the limbus of the exposed eye. Seven days after exposure, the lenses were macroscopically imaged and light scattering was quantitatively measured. The average maximum temperature increases for exposure times of 10, 18, 33, and 60 min were expressed as 7.0 ± 1.1, 6.8 ± 1.1, 7.6 ± 1.3, and 7.4 ± 1.1 °C [CI (0.95)] at the limbus of the exposed eye. The difference of light scattering in the lenses between exposed and contralateral not-exposed eyes was 0.00 ± 0.02, 0.01 ± 0.03, -0.01 ± 0.02, and -0.01 ± 0.03 transformed equivalent diazepam concentration (tEDC), respectively, and no apparent morphological changes in the lens were observed. An exposure to 96-W/cm(2) 1090-nm IRR projected on the cornea within the dilated pupil accumulating radiant exposures up to 344 kJ/cm(2) does not induce cataract if the temperature rise at the limbus is <8 °C. This is consistent with a thermal damage mechanism for IRR-induced cataract.
منابع مشابه
Damage mechanisms for near- infrared radiation induced cataract
Yu, Z. 2017. Damage mechanisms for near-infrared radiation induced cataract. Purpose: 1) To estimate the threshold dose and the time evolution for cataract induction by near infrared radiation (IRR) in seconds exposure time domain; 2) to determine the ocular temperature development during the threshold exposure; 3) to investigate if near IRR induces cumulative lens damage considering irradiance...
متن کاملOcular temperature elevation induced by threshold in vivo exposure to 1090-nm infrared radiation and associated heat diffusion.
An in vivo exposure to 197 W/cm 2 1090-nm infrared radiation (IRR) requires a minimum 8 s for cataract induction. The present study aims to determine the ocular temperature evolution and the associated heat flow at the same exposure conditions. Two groups of 12 rats were unilaterally exposed within the dilated pupil with a close to collimated beam between lens and retina. Temperature was recor...
متن کاملBilateral Macular Hemorrhage Due to Welding Arc: A Case Report
Background and Objective: Non-ionized radiation from arc welding may cause retinal lesions such as photo retinitis. In this report, a patient with bilateral macular bleeding which had been caused by inappropriate use of protective safety glasses is introduced. Case Report: On 26 July 2008 a 23-year-old male with blurred vision was referred to Shahid Beheshti's faculty of Rehabilitation Clinic....
متن کاملIn-vitro Study of Photothermal Anticancer Activity of Carboxylated Multiwalled Carbon Nanotubes
Background and Objective: Multi-walled Carbon Nano Tubes (MWCNTs) as an important element of nanosciences have a remarkable absorption in the region of NIR window (650-900 nm) which can overcome the limitations of deep treatment in photothermal therapy. To disperse MWCNTs in water, it is proposed to attach carboxylated functional group (-COOH) to MWCNTs in order to increase dispersivity in wate...
متن کاملEffect of Exposure to 900 MHz GSM Mobile Phone Radiofrequency Radiation on Estrogen Receptor Methylation Status in Colon Cells of Male Sprague Dawley Rats
Background: Over the past several years, the rapidly increasing use of mobile phones has raised global concerns about the biological effects of exposure to radiofrequency (RF) radiation. Numerous studies have shown that exposure to electromagnetic fields (EMFs) can be associated with effects on the nervous, endocrine, immune, cardiovascular, hematopoietic and ocular systems. In spite of genetic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 20 1 شماره
صفحات -
تاریخ انتشار 2015