Technical note: Artificial vagina vs a vaginal collection vial for collecting semen from rams.

نویسندگان

  • M C Wulster-Radcliffe
  • M A Williams
  • J N Stellflug
  • G S Lewis
چکیده

The time required to train rams to an artificial vagina (AV) makes collecting semen from large numbers of rams difficult. To manage this problem, we developed a glass, round-bottomed, 1.9-cm i.d. x 9.8-cm long vaginal collection vial (VCV). Three experiments were conducted to determine whether the VCV affected 1) semen volume per collection, 2) percentage of motile spermatozoa, 3) forward progressive motility score before and after extension and after freezing and thawing, and 4) our ability to collect semen from untrained rams. A soft rubber cap with a hole in the center was used to cover the VCV. A VCV was inserted into the vagina of an estrual ewe, and a monofilament line attached to the VCV was clipped to the wool near the vulva. Rams were joined with unrestrained ewes in a pen until they ejaculated into the VCV. In Exp. 1, five rams trained to an AV were used in a switchback design with four collection periods. During each period (1 d), semen was collected with an AV and a VCV. Immediately after collection, semen volume and sperm motility were quantified. Semen was extended with an aloe vera gel-based diluent at a 1:4 dilution rate, motility was quantified again, and semen was frozen. At 1 h after freezing, semen was thawed and sperm motility was quantified. Ejaculate volume (mean = 0.7 mL) and all measures of motility after collection were similar (P > 0.05) for the two collection methods. In Exp. 2, 10 rams trained to an AV were used in a switchback design with five collection periods (period = 3 d). On d 1 and 3 of each period, an AV and a VCV were used to collect semen. Collection method did not affect (P > 0.05) ejaculate volume (mean = 1.0 mL), percentage of motile cells, or forward progressive motility score. In Exp. 3, 51 untrained rams were used in a switchback design with a single collection period (2 d). Semen was collected with an AV and a VCV. Ability to collect an ejaculate and time required for collection were recorded. The likelihood of collecting semen from untrained rams was greater (P < 0.01) using a VCV (mean = 31.4%) than using an AV (mean = 9.8%). Collection method did not affect (P > 0.05) ejaculate volume (mean = 0.8 mL), percentage of motile cells, or forward progressive motility score. We concluded that a VCV could be used to collect semen from rams that are not trained for semen collection without decreasing ejaculate volume or sperm motility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison Of Ram Semen Collected By Artificial Vagina and Electro- Ejaculation

N. Matthews, N. Bester, and L.M. J. Schwalbach Department of Animal-Wildlife-and Grassland Sciences, University of the Free State, P.O.Box 339, Bloemfontein, 9300 _______________________________________________________________________________________ Abstract This aim of this study was to compare the quality of ram semen samples collected by means of artificial vagina and by electro-ejaculation...

متن کامل

O-4: Effects of Fatty Acid Sources in Diet onSperm Characteristics of Iranian Ram

Background: Researchers have indicated that mammalian spermatozoa are characterized by a high proportion of saturated, n-6 and n-3 series of fatty acids (FA). Major FA in rams’ sperm consists of C16, C18:1 and C22:6 (DHA). Little information exists on the effective use of saturated and unsaturated FA for ram whereas lipids have important role in sperm fertility. Our Background was to determine ...

متن کامل

Effect of ewe breed on the reaction time and semen characteristics in the ram

The aim of this study was to determine the effect of ewe breed on the reaction time and semencharacteristics in the ram. For this purpose, from the native sheep breeds in Iran, seven Lory rams and fourewes (two Lory and two Ghezel breeds) were selected. Seven rams were individually subjected to 4 weeklytrials in which one of the following two treatments was applied alternately. All of rams were...

متن کامل

Technic for Obtaining Spermatozoa for Physio- Logical Dairy Studies and Artificial Insemi-

Semen may be collected from the vagina of the recently bred cow with the hand, by aspiration, or with a sponge. Semen from the vagina is satisfactory for determining whether the bull has ejaculated normal active spermatozoa during the mating, but it is unsatisfactory for use in physiological studies of spermatozoa because it is mixed with the secretions of the cow. Furthermore, collecting semen...

متن کامل

Seasonal variation in semen characteristics of Chios and Friesian rams in Greece.

Five Chios and five Friesian rams were used to study the effect of season on semen production. Semen samples were collected with an artificial vagina. In spite of the large variation of most of the semen characteristics among rams of the two breeds, seasonal variation in semen quantity (volume, concentration and total number of spermatozoa per ejaculate) and quality (percentage of motile sperma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of animal science

دوره 79 12  شماره 

صفحات  -

تاریخ انتشار 2001