Nonthoracotomy- versus thoracotomy-implantable defibrillators. Intention-to-treat comparison of clinical outcomes.

نویسندگان

  • J M Kleman
  • L W Castle
  • G A Kidwell
  • J D Maloney
  • V A Morant
  • R G Trohman
  • B L Wilkoff
  • P M McCarthy
  • S L Pinski
چکیده

BACKGROUND Nonthoracotomy-implantable cardioverter/defibrillator (ICD) systems may represent a significant advance in the treatment of patients with life-threatening ventricular arrhythmias, but their merits relative to those of the well-established thoracotomy systems remain largely unknown. The objective of this study was to compare the short- and long-term clinical outcomes after attempted ICD implantation via a nonthoracotomy versus thoracotomy approach in similar groups of patients. METHODS AND RESULTS Between September 1990 and December 1992, 212 consecutive patients underwent attempted ICD system implantation without concomitant cardiac surgery at a single institution. Approach selection was not randomized but rather was based primarily on hardware availability. Primary comparisons of short- and long-term outcome were performed according to the "intention-to-treat" principle. Implantation was attempted via a nonthoracotomy approach in 120 patients (57%) and via a thoracotomy approach in 92 patients (43%). Prior cardiac surgery was more prevalent in the nonthoracotomy patients; otherwise, groups did not differ significantly in terms of prognostically relevant clinical characteristics. Nonthoracotomy implantation was successful in 101 patients (84%). After crossover to thoracotomy implantation (14 patients), the eventual success rate for ICD system implantation was 96% in the nonthoracotomy group. Thoracotomy implantation was successful in 89 patients (97%). Operative mortality was 3.3% in the nonthoracotomy and 4.3% in the thoracotomy groups (P = .73). Nonthoracotomy group patients were less likely to experience postoperative congestive heart failure (6% versus 16%; P = .02) or supraventricular arrhythmia (6% versus 18%; P = .004) and had significantly shorter postoperative intensive care and total hospitalization. Total hospital costs were significantly lower in the nonthoracotomy group ($32,205 versus $37,265; P = .001). After a follow-up of 16 +/- 9 months, there were 17 deaths in the nonthoracotomy group (none sudden) and 12 deaths in the thoracotomy group (1 sudden). One- and 2-year Kaplan-Meier survival probabilities were .87 (95% CI, .78 to .91) and .80 (95% CI, .68 to .88) in the nonthoracotomy group and .90 (95% CI, .82 to .95) and .87 (95% CI, .77 to .93) in the thoracotomy group (P = .56; log-rank test). CONCLUSIONS Nonthoracotomy ICD implantation is associated with reduced surgical morbidity, postoperative hospital care requirement, and hospital costs and has similar efficacy in preventing sudden death relative to the thoracotomy approach. From these nonrandomized data, it appears that a nonthoracotomy approach should be considered preferable in most patients requiring ICD therapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thoracotomy-Implantable Defibrillators Intention-to-Treat Comparison of Clinical Outcomes

Background Nonthoracotomy-implantable cardioverter/defibrillator (ICD) systems may represent a significant advance in the treatment of patients with life-threatening ventricular arrhythmias, but their merits relative to those of the wellestablished thoracotomy systems remain largely unknown. The objective of this study was to compare the shortand long-term clinical outcomes after attempted ICD ...

متن کامل

Intention-to-Treat Comparison of Clinical Outcomes

Background Nonthoracotomy-implantable cardioverter/defibrillator (ICD) systems may represent a significant advance in the treatment of patients with life-threatening ventricular arrhythmias, but their merits relative to those of the wellestablished thoracotomy systems remain largely unknown. The objective of this study was to compare the shortand long-term clinical outcomes after attempted ICD ...

متن کامل

Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: a systematic review of randomized clinical trials.

The number of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy (CRT) implantations is increasing drastically worldwide, and hence, the number of implanting centers is also increasing. Despite abundant data on the beneficial effect of these devices, little is known regarding safety and complication rates. Eleven ICD and 7 CRT trials were systematically reviewed ...

متن کامل

Cost and length of hospital stay: comparisons between nonthoracotomy and epicardial techniques in patients receiving implantable cardioverter defibrillators.

Twenty-five patients with implantable cardioverter defibrillators (ICDs) implanted intrathoracically (group I) were compared with 25 patients who underwent implant using the nonthoracotomy approach (group II). All systems were implanted by the same medical team, in the same high volume implanting center. Indications for implantation were comparable in both groups. Patient characteristics were n...

متن کامل

A permanent transvenous lead system for an implantable pacemaker cardioverter-defibrillator. Nonthoracotomy approach to implantation.

A transvenous lead system for implantable defibrillators would obviate a surgical thoracotomy and reduce the morbidity and mortality associated with implantation. We evaluated the clinical performance of a new nonthoracotomy lead system that included a defibrillation lead in the coronary sinus. At the time of defibrillator implantation, transvenous defibrillation leads were inserted percutaneou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 90 6  شماره 

صفحات  -

تاریخ انتشار 1994