Use of the Frank sequence in pulsed EPR.
نویسندگان
چکیده
The Frank polyphase sequence has been applied to pulsed EPR of triarylmethyl radicals at 25 6 MHz (9.1 mT magnetic field), using 256 phase pulses. In EPR, as in NMR, use of a Frank sequence of phase steps permits pulsed FID signal acquisition with very low power microwave/RF pulses (ca. 1.5 mW in the application reported here) relative to standard pulsed EPR. A 0.2 mM aqueous solution of a triarylmethyl radical was studied using a 16 mm diameter cross-loop resonator to isolate the EPR signal detection system from the incident pulses.
منابع مشابه
Demystifying EPR: A Rookie Guide to the Application of Electron Paramagnetic Resonance Spectroscopy on Biomolecules
Electron Paramagnetic Resonance (EPR) spectroscopy, also known as Electron Spin Resonance(ESR) especially among physicists, is a strong and versatile spectroscopic method forinvestigation of paramagnetic systems, i.e. systems like free radicals and most transition metalions, which have unpaired electrons. The sensitivity and selectivity of EPR are notable andintriguing as compared to other spec...
متن کاملPulse Programmer for Electron Paramagnetic Resonance Spectroscopy
The design of a new pulse programmer is presented. It is based on an application-specific integrated circuit (ASIC) and designed to fulfill the requirements of pulse electron paramagnetic resonance (EPR). The pulse EPR ASIC provides a high time resolution (2 ns) and a high channel density (8 channels per chip). The pulse sequences are controlled by a digital signal processor (DSP). The sequence...
متن کاملبررسی اثر محلول بر طیف EPR ناشی از رادیکالهای آلانین بر پایه نظریه تابعی چگالی
In this study, based on Density Functional Theory (DFT), the effect of solution on the g-tensor, hyperfine coupling constant of atoms and finally the EPR spectrum of alanine free radicals induced by ionizing radiation such as electron and gamma was investigated using implicit models such as COSMO, and explicit models such as introducing hydrogen bonds to the cluster structures. The obtained res...
متن کاملRetrospective dosimetry using fingernail in nuclear industries: A review paper
Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...
متن کاملPulsed 180-GHz EPR/ENDOR/PELDOR spectroscopy.
Within this review, we describe a home-built pulsed electron paramagnetic resonance (EPR) spectrometer operating at 180 GHz as well as the incorporation of two double resonance techniques, electron nuclear double resonance (ENDOR) and pulsed electron double resonance (PELDOR), along with first applications. Hahn-echo decays on a TEMPO/polystyrene sample are presented, demonstrating that the obs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance
دوره 209 2 شماره
صفحات -