The impact of non-drug-related toxicities on the estimation of the maximum tolerated dose in phase I trials.

نویسندگان

  • Alexia Iasonos
  • Mrinal Gounder
  • David R Spriggs
  • John F Gerecitano
  • David M Hyman
  • Sarah Zohar
  • John O'Quigley
چکیده

The rate of observed dose-limiting toxicities (DLT) determines the maximum tolerated dose (MTD) in phase I trials. There are cases in which non-drug-related toxicities or other-cause toxicities (OCT) are flagged as DLTs, or vice versa, due to attribution errors. We aim to assess the impact of such errors on the final estimate of MTD. We compared the impact of attribution errors using 2 trial designs-the "3+3" dose-escalation scheme and the continual reassessment method (CRM). Two attribution errors are considered: when a DLT is classified as an OCT (type A error) and when an OCT is misclassified as a DLT (type B error). The impact of these errors on accuracy, patient safety, sample size, and study duration was evaluated by varying the probability of occurrence of each error through simulated trials. Under no errors, CRM is on average 35% more accurate than 3+3 in finding the true MTD. This improved accuracy is maintained in the presence of errors. At a 15% type B error rate, CRM recommends a dose within 2 levels of the true MTD 68% of the time, compared with 17% of the time using the 3+3 method. A DLT must be attributed as an OCT 30% of the time to increase the accuracy of 3+3; otherwise the method recommends a wrong dose approximately 75% of the time. CRM is more robust to toxicity attribution errors compared with the 3+3 as it uses information from all treated patients, leading to a more accurate MTD estimation at the frequency of attribution errors anticipated in phase I clinical trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A phase I/II clinical trial for adult recurrent glioma using 131i-tm-601, an iodinated peptide derived from scorpion venom

131I-TM-601 is a 36-amino acid peptide, called chlorotoxin (TM-601), derived from scorpion venom labeled with I-131. TM-601 binds a receptor on the surface of tumor cells, and not on normal cells. A single dose of 131I-TM-601 administered intracranially to human xenografted mouse models of glioma has been shown to extend survival up to 269% in multiple studies. 131I-TM-601 is in a multi-center ...

متن کامل

A phase I/II clinical trial for adult recurrent glioma using 131i-tm-601, an iodinated peptide derived from scorpion venom

131I-TM-601 is a 36-amino acid peptide, called chlorotoxin (TM-601), derived from scorpion venom labeled with I-131. TM-601 binds a receptor on the surface of tumor cells, and not on normal cells. A single dose of 131I-TM-601 administered intracranially to human xenografted mouse models of glioma has been shown to extend survival up to 269% in multiple studies. 131I-TM-601 is in a multi-center ...

متن کامل

Predictive value of phase I trials for safety in later trials and final approved dose: analysis of 61 approved cancer drugs.

Phase I trials use a small number of patients to define a maximum tolerated dose (MTD) and the safety of new agents. We compared data from phase I and registration trials to determine whether early trials predicted later safety and final dose. We searched the U.S. Food and Drug Administration (FDA) website for drugs approved in nonpediatric cancers (January 1990-October 2012). The recommended p...

متن کامل

Adaptive Estimation of Personalized Maximum Tolerated Dose in Cancer Phase I Clinical Trials Based on All Toxicities and Individual Genomic Profile

BACKGROUND Many biomarkers have been shown to be associated with the efficacy of cancer therapy. Estimation of personalized maximum tolerated doses (pMTDs) is a critical step toward personalized medicine, which aims to maximize the therapeutic effect of a treatment for individual patients. In this study, we have established a Bayesian adaptive Phase I design which can estimate pMTDs by utilizin...

متن کامل

Dose‐finding methods for Phase I clinical trials using pharmacokinetics in small populations

The aim of phase I clinical trials is to obtain reliable information on safety, tolerability, pharmacokinetics (PK), and mechanism of action of drugs with the objective of determining the maximum tolerated dose (MTD). In most phase I studies, dose-finding and PK analysis are done separately and no attempt is made to combine them during dose allocation. In cases such as rare diseases, paediatric...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical cancer research : an official journal of the American Association for Cancer Research

دوره 18 19  شماره 

صفحات  -

تاریخ انتشار 2012