Bacterial colonization of chronic hemodialysis catheters: Evaluation with endoluminal brushes and heparin aspirate.
نویسندگان
چکیده
Tunneled catheters serve as interim access during maturation of a graft or fistula, or as a permanent vascular access in those patients who have exhausted their traditional access sites. However, bacteremia rates are high in patients with chronic catheters and indiscriminate removal of catheters during bacteremia increases morbidity and costs. A method to identify whether a catheter was colonized with the offending bacteria, without requiring catheter removal is desirable. We compared endoluminal brushing and heparin aspiration, to detect catheter colonization, in 24 asymptomatic patients undergoing elective tunneled hemodialysis catheter removal. The incidence of catheter colonization was highly correlated with catheter duration of inverted exclamation markY 30 days (p=0.03). Staphylococcus epidermidis represented 68% of the organisms isolated. No other organism accounted for more than 7% of the total. Fifteen (62.5%) of the 24 catheters had positive cultures. Eleven of the catheters were positive by culture of heparin aspirate and eight were positive by endoluminal brushing. Only four of the catheters were positive by both methods. The arterial lumen was more likely to have positive cultures than the venous lumen using either method. In this prospective investigation of tunneled hemodialysis catheters in asymptomatic patients we have demonstrated that a heparin aspirate sample is more likely to detect catheter colonization than a sample obtained using an endoluminal brush. Furthermore, 75% of catheters present for more than 30 days were colonized. Further study is needed to determine if the heparin aspirate method could be used in patients with bacteremia to accurately identify catheters that need removal.
منابع مشابه
Evaluation of a novel lysis catheter infections: A prospective, randomized trial of an endoluminal brush method for in situ diagnosis of catheter attachable silver-impregnated cuff for prevention of catheter-
of a Dacron cuffed hemodialysis catheter for prolonged use. Am 12. Blot F, Schmidt E, Nitenberg G et al. Earlier positivity of central-venousversus peripheral-blood cultures is highly preJ Kidney Dis 1988; 11: 166 dictive of catheter-related sepsis. J Clin Microbiol 1998; 36: 3. Moss AH, Vasilakis C, Holley JL et al. Use of a silicone dual 105–109 lumen catheter with a Dacron cuff as long-term ...
متن کاملEndoluminal dilatation for embedded hemodialysis catheters: A case-control study of factors associated with embedding and clinical outcomes
BACKGROUND With the increasing frequency of tunneled hemodialysis catheter use there is a parallel increase in the need for removal and/or exchange. A small but significant minority of catheters become embedded or 'stuck' and cannot be removed by traditional means. Management of embedded catheters involves cutting the catheter, burying the retained fragment with a subsequent increased risk of i...
متن کاملSuccessful prevention of tunneled, central catheter infection by antibiotic lock therapy using cefotaxime
BACKGROUND Chronic hemodialysis patients frequently require vascular access through central venous catheters (CVCs). The most significant complication of these catheters is infection. This risk can be lowered by the use of an antibiotic-Heparin lock. This study focuses on hemodialysis patients using Tunneled-cuffed catheters (TCC), to assess the rate of catheter-related infections (CRI) in cath...
متن کاملA novel antimicrobial and antithrombotic lock solution for hemodialysis catheters: a multi-center, controlled, randomized trial.
BACKGROUND AND PURPOSE Catheter-related bloodstream infection is the greatest threat to the safety of patients on hemodialysis. Catheter lock solutions containing heparin have been linked to an increased risk of hemorrhage and thrombocytopenia. OBJECTIVES To ascertain the safety and efficacy for prevention of catheter-related bloodstream infection and catheter loss from patency failure of a n...
متن کاملConcentrated Sodium Citrate (23%) for Catheter Lock.
For chronic central venous dialysis catheters, the standard method for maintaining catheter patency between treatments is to instill (lock) catheters with 5000 - 10 000 units of heparin in each lumen. Sodium citrate (citrate) is an anticoagulant with intrinsic antibacterial activity (at 20% concentration or higher). Citrate has only transient anticoagulant effects if accidentally infused to the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of vascular access
دوره 3 1 شماره
صفحات -
تاریخ انتشار 2002