The effect of operative factors on outlier ion levels in patients with metal-on-metal hip arthroplasties.
نویسندگان
چکیده
UNLABELLED Metal-on-metal (MoM) hip arthroplasties comprised of cobalt and chromium alloys continue to be successful alternatives to conventional bearings in younger patients with osteoarthritis (OA). A small proportion of patients have unusually high levels of cobalt and chromium ions postoperatively. Given the increasing prevalence of MoM bearings and the potential for cellular toxicity, the purpose of our study was to determine whether patient or surgical factors could account for abnormally elevated ion levels following MoM hip arthroplasty. MATERIALS AND METHODS Cobalt and chromium levels were analyzed from whole blood in 761 patients with MoM hip arthroplasties. Patient outliers were defined as those who had ion levels greater than or equal to three-fold the median value. Thirty-four patients (4.5%) met this criteria. This included 20 patients who underwent standard total hip arthroplasty (THA) and hip resurfacing, respectively. Patients were followed prospectively with the Harris hip scores (HHS) and the University of California Los Angeles (UCLA) activity scores. Serial radiographs and ion levels were analyzed at regular intervals. RESULTS At a mean follow-up of 2 years, the median values for outlier cobalt and chromium ions were 13.7 µg/L and 6.0 µg/L, respectively. Postoperative HHS and UCLA activity scores improved significantly when compared to pre-operative values. There was no statistical correlation between outlier ion levels, patient demographics, and HHS and UCLA activity scores. Acetabular inclination correlated with chromium values. Outlier cobalt levels were higher in patients after THA. CONCLUSIONS We identified that various patient and surgical factors could account for some of the abnormally high metal ion levels in outliers. Further studies are necessary to better understand the effect of abnormal elevations in metal ions, given the recent concerns of adverse local soft tissue reactions following MoM hip implants.
منابع مشابه
Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis
BACKGROUND Metal-on-metal (MOM) total hip arthroplasties were reintroduced because of the problems with osteolysis and aseptic loosening related to polyethylene wear of early metal-on-polyethylene (MOP) arthroplasties. The volumetric wear rate has been greatly reduced with MOM arthroplasties; however, because of nano-size wear particles, the absolute number has been greatly increased. Thus, a s...
متن کاملBlood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty: four-year results of a prospective longitudinal study.
This is a longitudinal study of the daily urinary output and the concentrations in whole blood of cobalt and chromium in patients with metal-on-metal resurfacings over a period of four years. Twelve-hour urine collections and whole blood specimens were collected before and periodically after a Birmingham hip resurfacing in 26 patients. All ion analyses were carried out using a high-resolution i...
متن کاملWorse health-related quality of life and hip function in female patients with elevated chromium levels
Background and purpose - Blood metal ion levels can be an indicator for detecting implant failure in metal-on-metal (MoM) hip arthroplasties. Little is known about the effect of bilateral MoM implants on metal ion levels and patient-reported outcomes. We compared unilateral patients and bilateral patients with either an ASR hip resurfacing (HR) or an ASR XL total hip replacement (THR) and inves...
متن کاملElevated Cobalt, Chromium and Molybdenum Levels in Peripheral Blood Have No Effect on the Development of Heterotopic Ossifications after Metal-on-Metal Total Hip Arthroplasty
Metal debris from metal-on-metal (MoM) total hip arthroplasties (THA) has been suspected to cause periprosthetic heterotopic ossifications (HO). We determined the influence of disseminated cobalt, chromium and molybdenum on the development of HO. Native blood samples from patients with 86 high-carbon and 16 low-carbon Co28Cr6Mo articulations were analysed by highresolution inductively coupled p...
متن کاملRevision of Metal-on-metal Hip Arthroplasty with Well Fixed and Positioned Acetabular Component Using a Dual-mobility Head and Review of Literature
BACKGROUND As a consequence of use of metal-on-metal hip arthroplasties some patients have precised revision for pain or metal hipersensivity reactions among other causes. We propose to salvage monoblock acetabular component and femoral component using a dual-mobility head and perform a lower morbidity operation in young patients preserving host bone stock in cases with well fixed and positione...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bulletin of the NYU hospital for joint diseases
دوره 69 Suppl 1 شماره
صفحات -
تاریخ انتشار 2011