Reduction of intubation rate during newborn resuscitation after transition from self-inflating bag to T-piece resuscitator.
نویسندگان
چکیده
INTRODUCTION T-piece resuscitator (TPR) has many advantages compared to self-inflating bag (SIB). Early Continuous Positive Airway Pressure (CPAP) during newborn resuscitation (NR) with TPR at delivery can reduce intubation rate. METHODS We speculated that the intubation rate at delivery room was high because SIB had always been used during NR and this can be improved with TPR. Intubation rate of newborn <24 hours of life was deemed high if >50%. An audit was carried out in June 2010 to verify this problem using a check sheet. RESULTS 25 neonates without major congenital anomalies who required NR with SIB at delivery were included. Intubation rate of babies <24 hours of life when SIB was used was 68%. Post-intervention audit (August to November 2010) on 25 newborns showed that the intubation rate within 24 hours dropped to 8% when TPR was used. Proportion of intubated babies reduced from 48.3% (2008-2009) to 35.1% (2011-2012), odds ratio 0.58 (95% CI 0.49-0.68). Proportion of neonates on CPAP increased from 63.5% (2008-2009) to 81.0% (2011-2012), odds ratio 2.44 (95% CI 2.03-2.93). Mean ventilation days fell to below 4 days after 2010. Since then, all delivery standbys were accompanied by TPR and it was used for all NR regardless of settings. There was decline in intubation rate secondary to early provision of CPAP with TPR during NR. Mean ventilation days, mortality and length of NICU stay were reduced. CONCLUSION This practice should be adopted by all hospitals in the country to achieve Millennium Development Goal 4 (2/3 decline of under 5 mortality rate) by 2015.
منابع مشابه
T-piece resuscitator versus self-inflating bag for preterm resuscitation: an institutional experience.
BACKGROUND Manual ventilation in the delivery room is provided with devices such as self-inflating bags (SIBs), flow-inflating bags, and T-piece resuscitators. OBJECTIVE To compare the effect of type of manual ventilation device on overall response to resuscitation among preterm neonates born at < 35 weeks gestation. METHODS Retrospective data were collected in 2 time periods. Primary outco...
متن کاملA survey of delivery room resuscitation practices in the United States.
OBJECTIVE To determine current resuscitation practices of neonatologists in the United States. METHODS A 15-question survey was developed and mailed to neonatal directors in May 2004. RESULTS Of the total of 797 surveys mailed, 84 were returned undeliverable or unanswered and 450 were returned completed (63% response rate). Respondents were mainly (70%) from level III NICUs. Most programs r...
متن کاملInnovating Neonatal Resuscitation Bags for Ease of Use in Diverse Locations.
The Chinese emperor Huang-Ti (2698–2599 BCE) noted that newborn death from ventilatory failure was common in premature infants.1 Galen (129–199 CE) inflated the lungs of deceased animals with a bellows and concluded that the air movement causes the chest to rise.1,2 Between 1850 and 1950, many techniques were used to resuscitate newborns, including swinging the infant upside down,1-3 rhythmic t...
متن کاملComparison of efficacy of three devices of manual positive pressure ventilation: a mannequin-based study
BACKGROUND We compared the efficacy of and consistency in manual ventilation by trained healthcare professionals using three devices: self-inflating bag, flow-inflating bag, and T-piece resuscitator. METHODS Prospective analytical study at a level III Neonatal unit of a tertiary care hospital. Forty participants (consultants, postgraduates, interns, and neonatal nurses - 10 each) manually ven...
متن کاملEffects of decreasing inspiratory flow rate during simulated basic life support ventilation of a cardiac arrest patient on lung and stomach tidal volumes.
If the airway of a cardiac arrest patient is unprotected, basic life support with low rather than high inspiratory flow rates may reduce stomach inflation. Further, if the inspiratory flow rate is fixed such as with a resuscitator performance may improve; especially when used by less experienced rescuers. The purpose of the present study was to assess the effect of limited flow ventilation on r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Medical journal of Malaysia
دوره 70 4 شماره
صفحات -
تاریخ انتشار 2015