Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: comparison with cine magnetic resonance imaging.
نویسندگان
چکیده
OBJECTIVES The purpose of this study was to determine whether contrast-enhanced transthoracic echocardiography improves the evaluation of left ventricular (LV) volumes and ejection fraction (EF). BACKGROUND Echocardiographic assessment of LV volumes and EF is widely used but may be inaccurate when the endocardium is not completely visualized. Recently the intravenous (i.v.) administration of perfluorocarbon microbubbles has been shown to enhance opacification of the LV cavity, but the utility of these agents to improve the echocardiographic assessment of LV systolic function is unknown. METHODS In 40 subjects (29 men and 11 women, aged 24 to 81 years) an assessment of LV volumes and EF was performed with a magnetic resonance imaging examination, followed immediately by a transthoracic echocardiogram before and after the intravenous administration of 2% dodecafluoropentane emulsion (EchoGen; Sonus Pharmaceuticals, Bothell, Washington). RESULTS Contrast enhanced the echocardiographic assessment of LV end diastolic volume (p < 0.02), end systolic volume (p < 0.01) and LVEF (p < 0.03). The percentage of subjects in whom the correct echocardiographic classification EF was normal, mild to moderately depressed or severely reduced improved significantly after contrast enhancement (from 71% before contrast to 94% after, p < 0.03). These findings were most striking in the subjects with two or more adjacent endocardial segments not visualized at baseline. CONCLUSIONS Administration of an intravenous contrast agent improves the ability to accurately assess LV volumes and EF in humans. Contrast enhancement is most useful in subjects with two or more adjacent endocardial segments not seen at baseline.
منابع مشابه
Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhanced and contrast-enhanced two-dimensional and three-dimensional echocardiography.
BACKGROUND Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV) functional analyses in the setting of two-dimensional (2D) echocardiography. The need for contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contra...
متن کاملAccurate and reproducible measurement of left ventricular volume and ejection fraction by contrast echocardiography: a comparison with magnetic resonance imaging.
OBJECTIVES We evaluated the accuracy and reproducibility of contrast echocardiography versus tissue harmonic imaging for measurements of left ventricular (LV) volumes and ejection fraction (EF) compared to magnetic resonance imaging (MRI). METHODS Digital echo recordings of apical LV views before and after intravenous contrast were collected from 110 consecutive patients. Magnetic resonance i...
متن کاملMeasurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE
AIM To compare three-dimensional (3D) k-t sensitivity encoded (k-t SENSE) cine cardiovascular magnetic resonance (CMR), before and after contrast administration, against standard 2D imaging for the assessment of left ventricular volumes and mass. METHOD Twenty-six subjects (14 volunteers, 12 patients) underwent multiple breathhold 2D balanced turbo-field echo cine CMR in addition to k-t SENSE...
متن کاملEvaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: comparison with left ventricular angiography.
Previous studies demonstrated that magnetic resonance (MR) imaging consistently underestimated angiographic measurements of left ventricular (LV) volumes. The purpose of this study was to determine whether MR imaging with steady-state free precession acquisition (SSFP) can provide improved accuracy and reproducibility in measuring cardiac function in comparison with fast spoiled gradient echo c...
متن کاملImproved quantitative assessment of left ventricular volumes using TGrE approach after application of extracellular contrast agent at 3 Tesla.
PURPOSE To prospectively determine whether the use of an extracellular contrast agent could improve the image quality of TGrE sequence for evaluation of left ventricular (LV) volumes and function, using a 3.0 T cardiovascular magnetic resonance (CMR) system. METHODS Fifteen consecutive patients underwent CMR imaging at 3.0 T. In each patient, 3 long axis views and multiple short axis slices w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 32 5 شماره
صفحات -
تاریخ انتشار 1998