Intraperitoneal hydrostatic pressure and flow characteristics of peritoneal catheters in automated peritoneal dialysis.

نویسندگان

  • Renzo Scanziani
  • Beatrice Dozio
  • Ivano Baragetti
  • Serena Maroni
چکیده

BACKGROUND In automated peritoneal dialysis (APD) one of the most important factors that influence the efficiency of the treatment is the total volume of dialysate infused per session and the dwell time. This study is aimed at examining the relationships between i.p. pressure (IPP), dialysate flow characteristics, and different dialysate fill volumes in order to optimize APD. METHODS We studied 20 patients who received APD, with the standard fill volume (2 l, A), or individualized fill volumes based on the patient's body surface area (2.5 l/BSA/1.73 m, B) or on body weight (40 ml/kg body weight, C). The patient's tolerance to a given fill volume was evaluated by measuring IPP, and catheter flow characteristics were evaluated by an automated machine. RESULTS IPP increased with the increase of the infused volume of dialysate (P < 0.05) and tended towards a positive relationship with the patient's body mass index (BMI: A vs IPP: R = 0.39, P = 0.0019; B vs IPP: R = 0.66, P = 0.0012; C vs IPP R = 0.55, P = 0.009). We also found a relationship between fill volume, BMI and IPP: IPP = 1.0839 + 0.53 (beta) x BMI + 0.211 (beta) x fill volume (R = 0.65; r(2) = 0.40 P < 0.01). The mean IPP with different dialysate fill volumes tended to be related to the volume of dialysate drained at the transition point (R = 0.37; P < 0.05). The pre-transition flow rate/mean IPP ratio tended towards a positive relationship with the volume of dialysate drained at the transition point (R = 0.35, P < 0.05), the transition time (R = 0.34; P < 0.05) and a negative one with the transition volume (R = -0.35, P = 0.05). CONCLUSION It is possible to customize APD, where the tidal percentage coincides with the transition point for a given catheter and a specific initial dialysate fill volume, the tolerance of which can be measured by assessing IPP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A mathematical model of peritoneal fluid absorption in tissue.

To investigate how water flow and interstitial pressure change in tissue during a peritoneal dwell with isotonic fluid, we developed a mathematical model of water transport in the tissue. Transport through muscle alone (M) and through muscle with intact skin (MS) were considered for the rat abdominal wall, using various parameters for muscle and skin. Based on the concept of distributed capilla...

متن کامل

Developing a Device for Automated Peritoneal Dialysis

Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...

متن کامل

Transport of protein in the abdominal wall during intraperitoneal therapy. I. Theoretical approach.

Intraperitoneal therapies such as peritoneal dialysis or regional chemotherapy use large volumes of solution within the peritoneal cavity. These volumes increase intraperitoneal hydrostatic pressure (P(ip)), which causes flow of the solution into tissues that surround the cavity. The goal of this paper is to integrate new experimental findings in a rigorous mathematical model to predict protein...

متن کامل

A Comparative Study on Using Coiled Versus Straight Swan-Neck Tenckhoff Catheters in Patients Undergoing Peritoneal Dialysis

The key to successful long-term peritoneal dialysis (PD) is permanent and safe access to peritoneal cavity. The two most commonly used Tenckoff catheters for PD are the straight and coiled catheters. The present study was undertaken to assess the catheter survival, catheter associated infections, and all cause mortality and to compare the straight with coiled catheters in PD. During April 1997-...

متن کامل

Distributed model of peritoneal fluid absorption.

The process of water reabsorption from the peritoneal cavity into the surrounding tissue substantially decreases the net ultrafiltration in patients on peritoneal dialysis. The goal of this study was to propose a mathematical model based on data from clinical studies and animal experiments to describe the changes in absorption rate, interstitial hydrostatic pressure, and tissue hydration caused...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 18 11  شماره 

صفحات  -

تاریخ انتشار 2003