Comparison of blind intubation through supraglottic devices and direct laryngoscopy by novices: a simulation manikin study
نویسندگان
چکیده
OBJECTIVE This study aimed to compare intubation performance between blind intubation through supraglottic airway devices and direct laryngoscopy by novices under manikin simulation. We hypothesized that the intubation time by novices using supraglottic airway devices was superior to that with the Macintosh laryngoscope (MCL). METHODS A prospective, randomized crossover study was conducted with 95 participants, to evaluate i-gel, air-Q, LMA Fastrach, and MCL devices. Primary outcomes were the intubation time and the success rate for intubation. RESULTS The i-gel showed the shortest insertion and tube passing time among the four devices; the i-gel and air-Q also showed the shortest total intubation time (all P<0.0083; i-gel vs. air-Q, P=0.03). The i-gel and MCL showed the highest cumulative success rate (all P<0.0083; i-gel vs. MCL, P=0.12). CONCLUSION Blind intubation through the i-gel showed almost equal intubation performance compared to direct laryngoscopy.
منابع مشابه
Comparison of direct intubation and Supraglottic Airway Laryngopharyngeal Tube (S.A.L.T.) for endotracheal intubation during cardiopulmonary resuscitation. Randomized manikin study.
BACKGROUND Airway control is a potentially lifesaving procedure, but intubation by direct laryngoscopy may be difficult. The aim of this study was to assess the success rate of tracheal intubation using the Macintosh laryngoscope and Supraglottic Airway Laryngopharyngeal Tube (S.A.L.T) device. METHODS This is a randomised cross-over study involving 120 paramedics utilising the Macintosh laryn...
متن کاملEstablishing a definitive airway in the trauma patient by novice intubators: A randomised crossover simulation study.
BACKGROUND Establishing a definitive airway, defined as a tube placed in the trachea with cuff inflated below the vocal cords, is standard of care in pre-hospital airway management of the trauma patient. However, in this setting, and using manual in-line stabilisation of the neck, success rate of intubation by inexperience providers is suboptimal. The use of supraglottic airway devices that all...
متن کاملUsefulness of video-laryngoscopy with the Airway Scope for intubation performance and learning: an experimental manikin controlled study
BACKGROUND Different video-laryngoscopes (VDLs) for endotracheal intubation (ETI) have recently been developed. We compared the performance of the VDL Airway Scope (AWS) with the direct laryngoscopy by Macintosh (DLM) for ETI success, time and learning. METHODS We performed an experimental manikin controlled study. Twenty experienced (experts) and 40 inexperienced operators (novices) for DLM-...
متن کاملComparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins
BACKGROUND Paramedics are frequently required to perform tracheal intubation, a potentially life-saving manoeuvre in severely ill patients, in the prehospital setting. However, direct laryngoscopy is often more difficult in this environment, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Airtraq and Truview laryngoscopes may...
متن کاملHands-Off Time for Endotracheal Intubation during CPR Is Not Altered by the Use of the C-MAC Video-Laryngoscope Compared to Conventional Direct Laryngoscopy. A Randomized Crossover Manikin Study
INTRODUCTION Sufficient ventilation and oxygenation through proper airway management is essential in patients undergoing cardio-pulmonary resuscitation (CPR). Although widely discussed, securing the airway using an endotracheal tube is considered the standard of care. Endotracheal intubation may be challenging and causes prolonged interruption of chest compressions. Videolaryngoscopes have been...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -