Determination of the electron's atomic mass and the proton/electron mass ratio via Penning trap mass spectroscopy.
نویسندگان
چکیده
Accuracy of the electron's atomic mass has been improved tenfold by comparing cyclotron frequencies of electrons and single C + ions alternately confined to the same uniform magnetic field in a Penning trap. Cyclotron resonances are observed via frequency shifts in the particle's continuously monitored harmonic motion parallel to the field. Field instability and relativity cause, respectively, the leading statistical and systematic errors. Combining the electron's atomic mass M, = 0.000548 579911 1(12) u with the proton's yields the mass ratio m~/m, = 1836.152 666 5(40).
منابع مشابه
Atomic mass of Li using a Penning-ion-trap mass spectrometer
The atomic mass of Li has been measured using a Penning-ion-trap mass spectrometer to be 6.015 122 795~16! u. The fractional measurement uncertainty of 62.7310 represents a 30-fold improvement over that of the accepted published value. External ion sources were used to create ions outside the cryogenic ~4 K! environment of the Penning trap and an ion-transport beamline was used to deliver ions ...
متن کاملFirst use of high charge states for mass measurements of short-lived nuclides in a Penning trap.
Penning trap mass measurements of short-lived nuclides have been performed for the first time with highly charged ions, using the TITAN facility at TRIUMF. Compared to singly charged ions, this provides an improvement in experimental precision that scales with the charge state q. Neutron-deficient Rb isotopes have been charge bred in an electron beam ion trap to q=8-12+ prior to injection into ...
متن کاملStudy of ground- and low-lying nuclear states by combining laser ionization and Penning trap mass spectrometry
The combination of resonant laser ionization, nuclear spectroscopy and mass measurements allows the deconvolution of the low-energy structure of atomic nuclei. Three β-decaying isomers of Cu have been unambiguously identified with the Penning trap mass spectrometer ISOLTRAP. In addition, isomerically pure ensembles of the short-lived radionuclides Cu have been prepared.
متن کاملNew determination of the electron's mass.
A new independent value for the electron's mass in units of the atomic mass unit is presented, m(e) = 0.000 548 579 909 2(4) u. The value is obtained from our recent measurement of the g factor of the electron in (12)C(5+) in combination with the most recent quantum electrodynamical (QED) predictions. In the QED corrections, terms of order alpha(2) were included by a perturbation expansion in Z...
متن کاملA Cooler Ion Trap for the TITAN On-line Trapping Facility at TRIUMF
We present simulations of electron and proton cooling of highly charged ions in a Penning trap, including the potentially detrimental effects of radiative, dielectronic, and three-body recombination in electron cooling. We show a preliminary design for a cooler trap accommodating both electron and proton cooling, which will be a component of the TITAN ion-trap facility under construction at TRI...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physical review letters
دوره 75 20 شماره
صفحات -
تاریخ انتشار 1995