Assessment of Damage on a Dual Mobility Acetabular System.
نویسندگان
چکیده
BACKGROUND Dual mobility designs were introduced to increase stability and reduce the risk of dislocation, both being common reasons for surgical revision after total hip arthroplasty. The in vivo behavior of dual mobility constructs remains unclear, and to our knowledge, no data have been published describing in vivo surface damage to the polyethylene bearing surfaces. METHODS We used surface damage assessed on the inner and outer polyethylene bearing surfaces in 33 short-term retrieved dual mobility liners as evidence of relative motion at the 2 bearings. A lever out test was performed to determine the force required for dislocation of the cobalt-chromium femoral head from the polyethylene liner. RESULTS Both bearings showed damage; however, the inner polyethylene bearings had higher damage scores, lower prevalence of remaining machining marks, and higher incidence of concentric wear, all consistent with more motion at the inner polyethylene bearing. The inner polyethylene bearings also had a higher occurrence of embedded titanium debris. The damage sustained in vivo was insufficient to lead to intraprosthetic dislocation in any of the retrieved components. Lever out tests of 12 retrievals had a mean dislocation load of 261 ± 52 N, which was unrelated to the length of implantation. CONCLUSION Our short-term retrieval data of 33 highly cross-linked polyethylene dual mobility components suggest that although motion occurs at both bearing articulations, the motion of the femoral head against the inner polyethylene bearing dominates. Although damage was not severe enough to lead to intraprosthetic dislocation, failure may occur long term and should be assessed in future studies.
منابع مشابه
Dissociation of Polyethylene Liner of the Dual Mobility Acetabular Component after Closed Reduction of Dislocation: A Case Report
A dual mobility acetabular component has a structure that combines a polyethylene liner and a femoral head, unlike the general design of acetabular cups, making the dissociation of a polyethylene liner highly unlikely. In addition, it increases the range of motion and reduces the possibility of dislocations by increasing a jump distance. A fifty-one-year-old male who had received total hip arth...
متن کاملCementation of a dual-mobility acetabular component into a well-fixed metal shell during revision total hip arthroplasty: a biomechanical validation.
Cementation of polyethylene (PE) liners into well-fixed metal shells has become a popular option during revision total hip arthroplasty (THA) particularly for older and frail patients. Although dramatic results were reported with dual-mobility acetabular components to manage hip instability during revision THA, no study evaluated the fixation strength of the cementation of dual-mobility compone...
متن کاملAcetabular reconstruction using a Kerboull cross-plate, structural allograft and cemented dual-mobility cup in revision THA at a minimum 5-year follow-up.
The current study aimed to evaluate the outcome of a continuous and prospective series of 61 revision THAs with AAOS grade III and IV acetabular bone defect reconstruction using a Kerboull cross-plate, structural allograft and cemented dual mobility cup (Saturne, Amplitude, Valence, France). At a 7.5-year mean follow-up, no instability was reported after revision. In addition, no failure of the...
متن کاملDual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture
BACKGROUND Hip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral neck fracture patients operated with a posterior approach with cemented conventional or dual articulation acetabular components. METHODS We compared the dislocation rate in 56 consecutive patients operated with c...
متن کاملEvaluation of Damage Distribution in Elements of Dual Frames
Researches show that the strength criterion is inadequate for design of structures against seismic loads. Since structures yield and experience plastic deformation under strong ground motion, considering structural damage with inelastic behavior may be a considerable criterion for design and control of the structures.In this paper, three steel structures with dual system consisting of intermedi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 31 8 شماره
صفحات -
تاریخ انتشار 2016