Modeling the frequency-dependent detective quantum efficiency of photon-counting x-ray detectors.

نویسنده

  • Karl Stierstorfer
چکیده

PURPOSE To find a simple model for the frequency-dependent detective quantum efficiency (DQE) of photon-counting detectors in the low flux limit. METHODS Formula for the spatial cross-talk, the noise power spectrum and the DQE of a photon-counting detector working at a given threshold are derived. Parameters are probabilities for types of events like single counts in the central pixel, double counts in the central pixel and a neighboring pixel or single count in a neighboring pixel only. These probabilities can be derived in a simple model by extensive use of Monte Carlo techniques: The Monte Carlo x-ray propagation program MOCASSIM is used to simulate the energy deposition from the x-rays in the detector material. A simple charge cloud model using Gaussian clouds of fixed width is used for the propagation of the electric charge generated by the primary interactions. Both stages are combined in a Monte Carlo simulation randomizing the location of impact which finally produces the required probabilities. The parameters of the charge cloud model are fitted to the spectral response to a polychromatic spectrum measured with our prototype detector. RESULTS Based on the Monte Carlo model, the DQE of photon-counting detectors as a function of spatial frequency is calculated for various pixel sizes, photon energies, and thresholds. CONCLUSION The frequency-dependent DQE of a photon-counting detector in the low flux limit can be described with an equation containing only a small set of probabilities as input. Estimates for the probabilities can be derived from a simple model of the detector physics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detective quantum efficiency dependence on x-ray energy weighting in mammography.

An evaluation of the dependence of detective quantum efficiency (DQE) on the incident energy spectrum has been made for mammography. The DQE dependence on the energy spectrum has been evaluated for energy-integrating detectors, photon-counting detectors, and detectors that measure the energy of each photon. To isolate the effect of the x-ray energy spectrum the detector has been assumed to be i...

متن کامل

Digital Mammography with a Photon Counting Detector in a Scanned Multislit Geometry

Mammography screening aims to reduce the number of breast cancer deaths by early detection of the disease, which is one of the leading causes of deaths for middle aged women in the western world. The risk from the x-ray radiation in mammography is relatively low but still a factor in the benefit-risk ratio of screening. The characterization and optimization of a digital mammography system is pr...

متن کامل

A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

PURPOSE One of the benefits of photon counting (PC) detectors over energy integrating (EI) detectors is the absence of many additive noise sources, such as electronic noise and secondary quantum noise. The purpose of this work is to demonstrate that thresholding voltage gains to detect individual x rays actually generates an unexpected source of white noise in photon counters. METHODS To dist...

متن کامل

Analysis of the spatial-frequency-dependent DQE of optically coupled digital mammography detectors.

The effect of optical coupling efficiency on the spatial-frequency-dependent propagation of signal and noise is considered for x-ray image detectors for digital mammography in which a phosphor screen is optically coupled to a charge-coupled device (CCD) image array. For experimental purposes, optical coupling between a Gd2O2S:Tb phosphor screen and a CCD image array was provided by relay lenses...

متن کامل

Fundamental x-ray interaction limits in diagnostic imaging detectors: frequency-dependent Swank noise.

A frequency-dependent x-ray Swank factor based on the "x-ray interaction" modulation transfer function and normalized noise power spectrum is determined from a Monte Carlo analysis. This factor was calculated in four converter materials: amorphous silicon (a-Si), amorphous selenium (a-Se), cesium iodide (CsI), and lead iodide (PbI2) for incident photon energies between 10 and 150 keV and variou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 2015