Comparing ultrasound measurements of neonatal hips using the methods of Graf and Terjesen.
نویسندگان
چکیده
In a prospective study, 232 neonates were examined sonographically using the methods of Graf and Terjesen. In order to determine the reproducibility of the methods, 50 hips were evaluated by two skilled examiners. In an inter-observer study, five physicians and five medical students evaluated 24 images, which were evaluated on ten occasions at two-weekly intervals by one of the authors. Statistical evaluation used the Bland-Altman approach. The neonates (110 females, 122 males) were less than four days old. The mean alpha angle was 62.4 degrees and mean femoral head cover was 55.4%. According to Graf's method, 1.3% of hips were pathological, compared with 4.1% according to Terjesen. Spearman's correlation coefficient between femoral head cover and alpha angles was 0.552. The Bland-Altman approach shows greater variation for femoral head cover than for alpha, if measured by experienced examiners. The Bland-Altman approach shows almost equal reproducibility for alpha and femoral head cover in the inter-observer test, but better repeatability for alpha in the intra-observer test. The Graf results relate better than Terjesen's to the well-known frequency of 1% to 2% hip dysplasia in the European population. Kappa statistics indicate a fair agreement between the two methods. Inter-observer evaluation shows an equal reproducibility of both methods, whereas intra-observer tests reveal better repeatability with Graf's method.
منابع مشابه
From DEPARTMENT OF WOMAN AND CHILD HEALTH Karolinska Institutet, Stockholm, Sweden DYNAMIC ULTRASONOGRAPHY IN NEONATAL HIP INSTABILITY AND ACETABULAR DYSPLASIA
The clinical hip examination, although highly sensitive in expert hands in detecting neonatal hip instability, can lead to considerable overtreatment. Ultrasound is increasingly being used to complement the clinical examination in assessing neonatal hip instability and acetabular dysplasia, often leading to increased treatment rate. Several different ultrasound methods are in use. In this thesi...
متن کاملDisparity between Clinical and Ultrasound Examinations in Neonatal Hip Screening
BACKGROUND For early detection of developmental dysplasia of the hip (DDH), neonatal hip screening using clinical examination and/or ultrasound has been recommended. Although there have been many studies on the reliability of both screening techniques, there is still controversy in the screening strategies; clinical vs. selective or universal ultrasound screening. To determine the screening str...
متن کاملThe use of ultrasound in determining the initiation of treatment in instability of the hip in neonates.
We have evaluated the effect of the use of ultrasound in determining the initiation of treatment in neonatal instability of the hip. A total of 99 newborn infants (1.5% of all live births) with neonatal hip instability did not have treatment from birth, but were re-examined at eight to 15 days. In the 31 who had persisting clinical instability and ultrasound abnormality, treatment was then star...
متن کاملAssessment of Diagnostic Value of Single View Dynamic Technique in Diagnosis of Developmental Dysplasia of Hip: A Comparison with Static and Dynamic Ultrasond Techniques
Background: Developmental dysplasia of hip (DDH) is a common childhood disorder, and ultrasonography examination is routinely used for screening purposes. In this study, we aimed to evaluate a modified combined static and dynamic ultrasound technique for the detection of DDH and to compare with the results of static and dynamic ultrasound techniques. Methods:In this cross-sectional study...
متن کاملHip abnormalities detected by ultrasound in clinically normal newborn infants.
We have followed the natural progress of newborn infants in whom ultrasound examination showed abnormalities in hips which appeared to be clinically normal. Over six years we saw 306 such children out of 9952 examined (31 per 1000 live births). The examination was repeated at two to three months and those who still showed an abnormality were followed up further. At four to five months a standar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 88 1 شماره
صفحات -
تاریخ انتشار 2006