On-line deoxygenation in reductive (and oxidative) amperometric detection: environmental applications in the liquid chromatography of organic peroxides

نویسنده

  • Otis Evans
چکیده

Cyclic voltammetry was used qualitatively to characterize and determine the feasibility of the oxidation and reduction of selected organic peroxides and hydroperoxides at a glassy carbon electrode. Organic peroxides were determined using reversed-phase high-performance liquid chromatography with simultaneous reductive and oxidative amperometric detection in a thin-layer dual parallel–adjacent electrode configuration. An on-line deoxygenator allowed the removal of molecular oxygen from the mobile phase and this resulted in an extension of the negative potential range of the glassy carbon electrode by approximately 750 ± 50 mV vs. the Ag/AgCl reference electrode. Chromatographically assisted hydrodynamic voltammetric measurements, in the dual parallel–adjacent electrode configuration, provided confirmation of the feasibility of simultaneously monitoring two independent redox reactions, for a single analyte, and allows for both the qualitative and quantitative analysis of organic peroxides (and hydroperoxides). The reductive amperometric responses were, on average, 2–5 times greater, depending on the particular organic peroxide, than the corresponding oxidative amperometric responses. An empirically determined parameter was evaluated and developed, {[iOxiRed] or [iaic]}, from two independent electrode reactions, that allows the qualitative identification of organic peroxide analytes by comparison of samples with standard injections. Estimated method detection limits (MDLs) for butan-2-one (butan-2-one) peroxide (2-BP), tert-butyl hydroperoxide (t-BHP) and cumene hydroperoxide (CHP) in reductive amperometry are approximately 0.8, 0.4 and 5 ppb, respectively and the oxidative amperometric MDLs are about 3, 2.5 and 12 ppb, respectively. The reductive amperometric responses for 2-BP, t-BHP and CHP are linear over 4–5 orders of magnitude of concentration, extending from ca. 1 mg l21 to ca. 100 mg l21, and the corresponding correlation coefficients are of the order of 0.9997–0.99994.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-performance liquid chromatography of selected organic peroxides with oxidative amperometric detection.

Reversed-phase high-performance liquid chromatography with oxidative amperometric detection was optimized for the determination of several organic peroxides in drinking water under ideal conditions. The determinations were performed under isocratic conditions using acetonitrile and methanol as the organic modifiers with 0.05 M potassium phosphate buffer solution. The oxidative amperometric resp...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Screening Method for Mononitrotoluenes in Natural Waters Using Magnetic Solvent Bar Liquid-Phase Micro-extraction Followed by Gas Chromatography-Flame Ionization Detection

A simple andefficient hollow fiber-based method,viz magnetic solvent bar liquid-phasemicroextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GCFID)has been successfully developed for the trace determination of mononitrotoluenes (MNTs) innatural water samples. The analytes were extracted from sample solution to the organic solventimmobilize...

متن کامل

Uncovering Deficiencies in Mass Balance Using HPLC with Chemiluminescence Nitrogen-Specific Detection

with amperometric detection. It has been shown elsewhere that the selectivity of this method is sufficient to separate the potential organic impurities; that is, synthesis byproducts and a specified degradation product from the drug substance (3). The objective of this article is to demonstrate that this method’s suitability for stability testing can be evaluated easily by performing HPLC with ...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999