Compton scattering imaging of a working battery using synchrotron high-energy X-rays

نویسندگان

  • Masayoshi Itou
  • Yuki Orikasa
  • Yuma Gogyo
  • Kosuke Suzuki
  • Hiroshi Sakurai
  • Yoshiharu Uchimoto
  • Yoshiharu Sakurai
چکیده

Results of studies on Compton scattering imaging using synchrotron high-energy X-rays are reported. The technique is applied to a discharging coin cell, and the intensity of Compton scattered X-rays from the inside of the cell has been measured as a function of position and time. The position-time intensity map captures the migration of lithium ions in the positive electrode and reveals the structural change due to the volume expansion of the electrode. This experiment is a critical step in developing synchrotron-based Compton scattering imaging for electrochemical cells at a product level.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Densitometry and temperature measurement of combustion gas by X-ray Compton scattering.

Measurement of combustion gas by high-energy X-ray Compton scattering is reported. The intensity of Compton-scattered X-rays has shown a position dependence across the flame of the combustion gas, allowing us to estimate the temperature distribution of the combustion flame. The energy spectra of Compton-scattered X-rays have revealed a significant difference across the combustion reaction zone,...

متن کامل

Linac-based Laser Compton Scattering X-ray and Gamma-ray Sources

Laser Compton scattering (LCS) light sources can provide high-energy photons from keV to MeV range. Many research and development projects of linac-based LCS sources are carried on. For the photon energies of tens keV, linac-based LCS sources realize laboratory-size X-ray sources, of which performance is potentially comparable to 2 generation synchrotron light sources. Linac-based LCS also real...

متن کامل

Study of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method

Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...

متن کامل

Time-dependent Synchrotron and Compton Spectra from Jets of Microquasars

Jet models for the high-energy emission of Galactic X-ray binary sources have regained significant interest with detailed spectral and timing studies of the X-ray emission from microquasars, the recent detection by the HESS collaboration of very-high-energy γ-rays from the microquasar LS 5039, and the earlier suggestion of jet models for ultraluminous X-ray sources observed in many nearby galax...

متن کامل

Inverse Compton X-ray Flare from GRB Reverse Shock

We study synchrotron self-inverse Compton radiation from a reverse-shocked fireball. If the inverse Compton process dominates the cooling of shocked electrons, an X-ray flare produced by the first order Compton scattering would emerge in the very early afterglow phase, with the bulk of the shock energy radiated in the second order scattering component at 10-100 MeV. The dominance of inverse Com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2015