Early Outcome of Prostate Intensity Modulated Radiation Therapy (IMRT) Incorporating a Simultaneous Intra-Prostatic MRI Directed Boost.

نویسندگان

  • Michael H Schild
  • Steven E Schild
  • William W Wong
  • Sujay A Vora
  • Alvin C Silva
  • Annelise M Silva
  • Thomas B Daniels
  • Sameer R Keole
چکیده

This study assessed the feasibility and outcomes of treating prostate cancer with intensity modulated radiotherapy (IMRT) incorporating a Magnetic Resonance Imaging (MRI) directed boost. Seventy-eight men received IMRT for localized prostate cancer. The entire prostate received 77.4Gy in 43 fractions and simultaneous intra-prostatic boosts (SIB) of 83Gy were administered to increase the dose to the MRI identified malignancy. In 16 (21%) patients, the MRI didn't detect a neoplasm and these patients received an SIB of 81Gy to the posterior prostate. Androgen Deprivation Therapy (ADT) was also administered to 32 (41%) patients. The 3-year rates of biochemical control, local control, distant control, and survival were 92%, 98%, 95%, and 95% respectively. While grade 1-2 toxicities were common, there were only 2 patients who suffered grade 3 toxicity. These patients developed strictures which were dilated resulting in improvement in symptoms such that both had grade 1-2 toxicity at last follow up examination. The results of this program of IMRT incorporating a MRI directed intra-prostatic boost suggest this technique is feasible and well tolerated. This technique appears to shift the therapeutic index favorably by boosting the malignancy to the highest dose without increasing the doses administered to the bladder and rectum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous integrated boost of biopsy proven, MRI defined dominant intra-prostatic lesions to 95 Gray with IMRT: early results of a phase I NCI study

BACKGROUND To assess the feasibility and early toxicity of selective, IMRT-based dose escalation (simultaneous integrated boost) to biopsy proven dominant intra-prostatic lesions visible on MRI. METHODS Patients with localized prostate cancer and an abnormality within the prostate on endorectal coil MRI were eligible. All patients underwent a MRI-guided transrectal biopsy at the location of t...

متن کامل

Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy

Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conformal radiation therapy (3D-CRT) and intensity modulated radiation therapy (IMRT) of prostate cancer.Methods and Materials: 10 prostate plans were randomly selected among patients ...

متن کامل

Image guided intensity modulated hypofractionated radiotherapy in high-risk prostate cancer patients treated four or five times per week: analysis of toxicity and preliminary results

BACKGROUND To evaluate efficacy and toxicity of hypofractionated intensity-modulated simultaneous integrated boost (IMRT-SIB) and image-guided (IGRT) radiotherapy in the treatment of high-risk prostate cancer patients. METHODS Eighty-two patients with high-risk prostate cancer were analysed. An IMRT treatment was planned delivering 68.75 Gy to the prostate, 55 Gy to the seminal vesicles and p...

متن کامل

Simultaneous integrated boost plan comparison of volumetric‐modulated arc therapy and sliding window intensity‐modulated radiotherapy for whole pelvis irradiation of locally advanced prostate cancer

Concurrent radiotherapy to the pelvis plus a prostate boost with long-term androgen deprivation is a standard of care for locally advanced prostate cancer. IMRT has the ability to deliver highly conformal dose to the target while lowering irradiation of critical organs around the prostate. Volumetric-modulated arc therapy is able to reduce treatment time, but its impact on organ sparing is stil...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • OMICS journal of radiology

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2014