Simultaneous determination of five commercial cationic dyes in stream waters using diatomite solid-phase extractant and multivariate calibration

نویسندگان

  • Yahya S. Al-Degs
  • Jamal A. Sweileh
چکیده

osting by E Abstract A simple spectrophotometric method was developed for the simultaneous determination of five commercial cationic dyes at 2.0 8.5 lg L 1 level after using diatomite as solid-phase extractant. The method is based on preconcentration of the five dyes on natural diatomite solid-phase extractant and on multivariate calibration using partial least squares method (PLS-1). Compared with commonly used chromatographic or electrophoretic methods the developed method is simple and sensitive. With enrichment factors between 89 and 96, diatomite outperformed zeolite and activated carbon for dyes preconcentration. Before preconcentration and using PLS-1 method, the cationic dyes were simultaneously analyzed with linear ranges of 0.18–4.5, 0.32–5.0, 0.23–4.5, 0.45–8.0 and 0.82–12.0 mg L 1 for crystal violet, malachite green, methylene blue, safranine O, and thioflavin T, respectively. The detection limits of dyes were estimated using Lorber’s method and found to be within the range 43–245 lg L . The proposed SPE/PLS-1 method was applied to spiked stream water samples with good accuracy (79–91%) and precision (RSD 1.8–7.3%) but with slightly lower enrichment factors (80–92). a 2010 King Saud University. Production and hosting by Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Solid Phase Extraction and Removal of Five Cationic Dyes from Aqueous Solution Using Magnetite Nanoparticle Loaded Platanusorientalis Waste Leaves

This paper reports on synthesis of a magnetic adsorbent for wastewater treatment purposes. In this regard, platanus orientalis waste leaves were chosen as a cheap material for preparing the magnetic adsorbent by loading magnetite nanoparticles on it. The synthesized adsorbent was characterized using scanning electron microscope and X-ray diffractometer. Then, it was used for magnetic solid phas...

متن کامل

Solid-phase extraction and simultaneous determination of trace amounts of sulphonated and azo sulphonated dyes using microemulsion-modified-zeolite and multivariate calibration.

A simple and rapid analytical method for the determination of trace levels of five sulphonated and azo sulphonated reactive dyes: Cibacron Reactive Blue 2 (C-Blue, trisulphonated dye), Cibacron Reactive Red 4 (C-Red, tetrasulphonated azo dye), Cibacron Reactive Yellow 2 (C-Yellow, trisulphonated azo dye), Levafix Brilliant Red E-4BA (L-Red, trisulphonated dye), and Levafix Brilliant Blue E-4BA ...

متن کامل

Simultaneous spectrophotometric determination of lidocaine and hydrocortisone acetate in pharmaceutical preparations by multivariate calibration methods

The multivariate calibration method, partial least square regression (PLS) was applied for thesimultaneous spectrophotometric determination of Lidocaine (LID) and Hydrocortisone acetate(HCA) in their mixtures. The parameters of chemometric technique were optimized and theproposed method was validated with synthetic samples and applied to analyze these drugs inpharmaceutical products with good a...

متن کامل

Simultaneous determination of the colorants sunset yellow FCF and quinoline yellow by solid-phase spectrophotometry using partial least squares multivariate calibration.

A method for the simultaneous determination of the colorants Sunset Yellow FCF and Quinoline Yellow using solid-phase spectrophotometry is proposed. The colorants were isolated in Sephadex DEAE A-25 gel at pH 5.0, the gel-colorants system was packed in a 1 mm silica cell and spectra were recorded between 400 and 600 nm against a blank. Statistical results were obtained by partial least squares ...

متن کامل

Simultaneous spectrophotometric determination of ampicillin and penicillin in human plasma using multivariate calibration

An analytical methodology based on spectrophotometric and partial least squares (PLS) algorithm for thesimultaneous determination of ampicillin and penicillin in human plasma was developed and validated. Themultivariate model was developed as a binary calibration model and it was built and validated with anindependent set of synthesis and real samples in presence of matrix. It is shown how a de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012