Floating Chip Mounting System Driven by Repulsive Force of Permanent Magnets for Multiple On-Site SPR Immunoassay Measurements

نویسندگان

  • Tsutomu Horiuchi
  • Tatsuya Tobita
  • Toru Miura
  • Yuzuru Iwasaki
  • Michiko Seyama
  • Suzuyo Inoue
  • Jun-ichi Takahashi
  • Tsuneyuki Haga
  • Emi Tamechika
چکیده

We have developed a measurement chip installation/removal mechanism for a surface plasmon resonance (SPR) immunoassay analysis instrument designed for frequent testing, which requires a rapid and easy technique for changing chips. The key components of the mechanism are refractive index matching gel coated on the rear of the SPR chip and a float that presses the chip down. The refractive index matching gel made it possible to optically couple the chip and the prism of the SPR instrument easily via elastic deformation with no air bubbles. The float has an autonomous attitude control function that keeps the chip parallel in relation to the SPR instrument by employing the repulsive force of permanent magnets between the float and a float guide located in the SPR instrument. This function is realized by balancing the upward elastic force of the gel and the downward force of the float, which experiences a leveling force from the float guide. This system makes it possible to start an SPR measurement immediately after chip installation and to remove the chip immediately after the measurement with a simple and easy method that does not require any fine adjustment. Our sensor chip, which we installed using this mounting system, successfully performed an immunoassay measurement on a model antigen (spiked human-IgG) in a model real sample (non-homogenized milk) that included many kinds of interfering foreign substances without any sample pre-treatment. The ease of the chip installation/removal operation and simple measurement procedure are suitable for frequent on-site agricultural, environmental and medical testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passive Fluidic Chip Composed of Integrated Vertical Capillary Tubes Developed for On-Site SPR Immunoassay Analysis Targeting Real Samples

We have successfully developed a surface plasmon resonance (SPR) measurement system for the on-site immunoassay of real samples. The system is composed of a portable SPR instrument (290 mm(W) × 160 mm(D) × 120 mm(H)) and a microfluidic immunoassay chip (16 mm(W) × 16 mm(D) × 4 mm(H)) that needs no external pump system. An integrated vertical capillary tube functions as a large volume (150 μL) p...

متن کامل

Force Sensing by Microrobot on a Chip

In this paper, we discuss a force sensing by microrobot called magnetically driven microtool (MMT) in a microfluidic chip. On-chip force sensor is fabricated by assembling layers to neglect the friction issue and it is actuated by permanent magnets, which supply mN order force to stimulate microorganisms. The displacement is magnified by designing beams on the force sensor and the sensor achiev...

متن کامل

Enucleation of Oocyte by On-chip robot driven by magnet with gripping mechanism

We developed a highly-functional untethered on-chip robot for cell handling and micro-knife made by Si to cut zona pellucida of oocyte. The on-chip robot has a gripping mechanism which can grasp a cell or micro-object with sufficient power. The position and handling force of the robot are controlled independently by the magnetic force. The permanent magnets and electrical magnet are assembled t...

متن کامل

On-Site Detection of Aflatoxin B1 in Grains by a Palm-Sized Surface Plasmon Resonance Sensor

Aflatoxins (AFs) are highly toxic compounds that can cause both acute and chronic toxicity in humans. Aflatoxin B1 (AFB1) is considered the most toxic of AFs. Therefore, the rapid and on-site detection of AFB1 is critical for food safety management. Here, we report the on-site detection of AFB1 in grains by a portable surface plasmon resonance (SPR) sensor. For the detection of AFB1, the surfac...

متن کامل

On-chip Dual Arm Microrobot for Cell Manipulations by Magnetically Driven Microtools

This paper presents the innovative driving method of on-chip dual arm microrobots to achieve precise cell manipulations. The positioning accuracy in the new driving method improves 5 times higher and the response speed becomes 10 times quicker against the driving stage than in the conventional method. Commercially available permanent magnets are used to actuate the microrobots owing to the cons...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2012