Variability of high-pass resolution perimetry in normals and patients with idiopathic intracranial hypertension.

نویسندگان

  • M Wall
  • J Lefante
  • M Conway
چکیده

High-pass resolution perimetry, or the "ring test," is a recently developed type of acuity perimetry. To determine its test-retest variability, we studied 10 normals and 10 patients with idiopathic intracranial hypertension (IIH) by testing both eyes four separate times. There was no increase in variability from the center out to 21 degrees of visual field eccentricity. However, there was a significant increase from 22 degrees to 29 degrees in both normals and IIH patients. Unlike light sensitivity threshold automated perimetry, with an increase in threshold level there was no significant increase in variability in either normals or patients. This may be because of the test's method, which thresholds by target size rather than intensity. As expected, there was a large intersubject variability in the patients, with the visual fields being significantly disturbed by analysis of total field, quadrants, concentric rings, and anatomic nerve fiber bundle regions. Surprisingly, there was no significant difference in the total within subject variability of normals and patients. Because with the ring test there is no increase in variability with an increase in threshold, this method of perimetry may have great utility for following patients with disturbed visual fields. The ring test appears to have advantages that promote low test-retest variability.

منابع مشابه

High-pass Resolution Neural Capacity and Retinal Nerve Fiber Layer Thickness in Glaucoma

The neural capacity (NC) of high-pass resolution perimetry (HRP) was compared to the retinal nerve fiber layer thickness measured with the GDx Nerve Fiber Analyzer in 74 patients with either ocular hypertension or primary open-angle glaucoma at various stages of severity. A statistically significant correlation was found between the NC and the GDx ellipse average, the total polar integral, and ...

متن کامل

Optic nerve diameters and perimetric thresholds in idiopathic intracranial hypertension.

AIMS/BACKGROUND Idiopathic intracranial hypertension (IIH) is a central nervous disorder characterised by abnormally increased cerebrospinal fluid (CSF) pressure leading to optic nerve compression. An indirect estimate of increased CSF pressure can be obtained by the ultrasonographic determination of optic nerve sheaths diameters. Computerised static perimetry is regarded as the method of choic...

متن کامل

Idiopathic intracranial hypertension.

Although the cause of IIH remains obscure, loss of visual function is common, and patients may progress to blindness. Diagnosis should adhere to the modified Dandy criteria. Recent case-control studies cast doubt on the validity of many frequently cited conditions associated with IIH. Valid associations include obesity, recent weight gain, female sex, vitamin A intoxication, and steroid withdra...

متن کامل

High spatial resolution automated perimetry in glaucoma.

BACKGROUND Automated perimetry is of fundamental importance in assessing visual function in glaucoma. A technique was evaluated to perform high spatial resolution automated perimetry to allow a more detailed assessment of the luminance sensitivity in selected regions of the visual field than is possible with conventional perimetry. METHOD High spatial resolution perimetry was performed using ...

متن کامل

University of Birmingham Headache determines quality of life in idiopathic intracranial hypertension

Background: The effect of idiopathic intracranial hypertension (IIH) on quality of life (QOL) is poorly understood. Our objectives were to compare QOL in IIH to the normal UK population; to investigate QOL changes with treatment of IIH, using a weight loss intervention, and to determine which clinical factors influence QOL. Methods: This was a prospective cohort evaluation of QOL, using the 36-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 32 12  شماره 

صفحات  -

تاریخ انتشار 1991