Transmitral Doppler: a new transthoracic contrast method for patent foramen ovale detection and quantification.

نویسندگان

  • A J Kerr
  • T Buck
  • K Chia
  • C M Chow
  • E Fox
  • R A Levine
  • M H Picard
چکیده

OBJECTIVES This study compared a new transthoracic echocardiographic (TTE) method for detection of right to left bubble passage, transmitral Doppler (TMD), against two-dimensional (2D) TTE contrast study and the gold standard, of transesophageal echocardiography (TEE), and assessed its utility in quantitative assessment of patent foramen ovales (PFO). BACKGROUND Current TTE methods are relatively insensitive in PFO detection and do not allow quantitative assessment of right to left shunt. METHODS In 44 patients (59 years, range 34 to 76 years) saline contrast and color Doppler studies were performed in three conditions--TTE TMD, TTE 2D and TEE. Bubble transit on the TMD was measured semiquantitatively by a visual bubble score and objectively by integrating the acoustic power within the mitral velocity envelope. RESULTS By TEE it was determined that 17 patients (39%) had PFOs; 16 had right to left contrast passage, and only 1 had left to right flow by color Doppler. Against TEE contrast study, the sensitivity of TMD and 2D contrast studies were 100% and 75%, respectively, with specificity of 96% and 100%. Greater than 10 bubbles on a single beat of the resting contrast TMD identified patients with a maximum resting TEE PFO opening diameter >2 mm with 78% sensitivity and 100% specificity. There was a strong correlation (r2 = 0.72, p<0.01) between the TMD acoustic power and PFO opening diameter. CONCLUSIONS Transmitral Doppler is a sensitive and specific method for TTE PFO detection that allows quantification of right to left bubble passage and may obviate the need for TEE in many patients after stroke.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Foramen Ovale in Stroke Patients

Background and Purpose: The prevalence of a patent foramen ovale has been shown to be increased in patients with ischemic stroke. Transesophageal echocardiography, transthoracic echocardiography, and transcranial Doppler examination with contrast injection can all be used to search for a patent foramen ovale. We compared the accuracy of these techniques for identifying a patent foramen ovale in...

متن کامل

Comparison of transthoracic echocardiography using second harmonic imaging, transcranial Doppler and transesophageal echocardiography for the detection of patent foramen ovale in stroke patients.

AIMS The comparison of three imaging methods to determine which is the most accurate and reliable for the detection of right-to-left shunt. METHODS AND RESULTS One hundred and seven patients who were hospitalized for stroke underwent: a transthoracic echocardiography (TTE) using second harmonic, a transcranial Doppler (TCD) and a transesophageal echocardiography (TEE) from August 2003 to Apri...

متن کامل

Diagnosis and quantification of patent foramen ovale. Which is the reference technique? Simultaneous study with transcranial Doppler, transthoracic and transesophageal echocardiography.

INTRODUCTION AND OBJECTIVES Patent foramen ovale (PFO) is the most common cause of cryptogenic stroke in patients younger than 55. Transesophageal echocardiography (TEE) has been accepted as the reference diagnostic technique. The purpose of this study was to compare the accuracy of transthoracic echocardiography (TTE), TEE and transcranial Doppler (TCD) in the diagnosis and quantification of p...

متن کامل

Patent foramen ovale: a review of associated conditions and the impact of physiological size.

Patent foramen ovale (PFO) is implicated in platypnea-orthodeoxia, stroke and decompression sickness (DCS) in divers and astronauts. However, PFO size in relation to clinical illness is largely unknown since few studies evaluate PFO, either functionally or anatomically. The autopsy incidence of PFO is approximately 27% and 6% for a large defect (0.6 cm to 1.0 cm). A PFO is often associated with...

متن کامل

Doppler-device Not known Quantification Cerebral microemboli during carotid artery endarterectomy and angioplasty with stenting Right to left shunt in cryptogenic stroke: TCD vs. TEE Author

Patent foramen ovale is frequently associated with embolic cerebrovascular accidents. The diagnosis of patent foramen ovale (PFO) is easier since the advent of transesophageal echocardiography but is invasive and does not allow to detect extracardiac RLS. Contrast transcranial Doppler ultrasound enables the detection of the passage of a contrast material injected into a peripheral vein to the c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2000