Corneal thickness and daily curve of intraocular pressure in suspected and glaucomatous patients.
نویسندگان
چکیده
PURPOSE To evaluate in suspected and glaucomatous patients the correlation between central corneal thickness (CCT) and intraocular pressure (IOP), measured during the daily curve of intraocular pressure (DCPo), including CCT and IOP measurements in bed at 6 am. The ocular axial length was also compared. METHODS 114 eyes from 73 patients, 30 eyes suspected of glaucoma (group I) and 84 eyes with chronic open-angle glaucoma (group II) were prospectively studied. Both groups were subjected to DCPo with measurements of IOP at 9 am, 12 pm, 6 pm, 10:30 pm and on the next day at 6 am in bed and in darkness before the patient gets up. Using the ultrasonic DGH 5100 device, CCT measurements were performed at 9 am, 6 pm, 10:30 pm and the next day at 6 am in bed before the patient gets up. The ocular axial length was also measured. RESULTS In the total sample and, separately in each group, the mean IOP was more elevated in bed at 6 am. There were no significant CCT changes during the day within each group or between both groups. No statistically significant difference was found between the mean ocular axial length of both groups. CONCLUSIONS In suspected and glaucomatous patients, there were no statistically significant CCT variations during the day; therefore, only one CCT measurement is sufficient. Also, there was no statistically significant difference between ocular axial length of both groups.
منابع مشابه
بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کاملCorrelation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کامل[Relationship between central corneal thickness, intraocular pressure and severity of glaucomatous visual field loss].
OBJECTIVE to determine central corneal thickness in normal subjects, glaucomatous patients and ocular hypertension patients, to evaluate if the central corneal thickness is related to the presence of glaucoma or ocular hypertension. Furthermore, we aim to verify the relationship between central corneal thickness and severity of glaucomatous visual field loss. METHODS comparative study includi...
متن کاملImportance of intraocular pressure measurement at 6:00 a.m. in bed and in darkness in suspected and glaucomatous patients.
PURPOSE To assess the importance of intraocular pressure measurement obtained at 6:00 a.m. in bed and darkness for the diagnosis and intraocular pressure control of primary open-angle glaucoma. METHODS Retrospective analysis of the daily curve of intraocular pressure of suspects and glaucomatous patients under treatment. Suspects were classified as intraocular pressure values ranging from 19 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de oftalmologia
دوره 68 2 شماره
صفحات -
تاریخ انتشار 2005