Measurement of fractional synthetic rates of multiple protein analytes by triple quadrupole mass spectrometry.
نویسندگان
چکیده
BACKGROUND Current approaches to measure protein turnover that use stable isotope-labeled tracers via GC-MS are limited to a small number of relatively abundant proteins. We developed a multiplexed liquid chromatography-selected reaction monitoring mass spectrometry (LC-SRM) assay to measure protein turnover and compared the fractional synthetic rates (FSRs) for 2 proteins, VLDL apolipoprotein B100 (VLDL apoB100) and HDL apoA-I, measured by both methods. We applied this technique to other proteins for which kinetics are not readily measured with GC-MS. METHODS Subjects were given a primed-constant infusion of [5,5,5-D(3)]-leucine (D(3)-leucine) for 15 h with blood samples collected at selected time points. Apolipoproteins isolated by SDS-PAGE from lipoprotein fractions were analyzed by GC-MS or an LC-SRM assay designed to measure the M+3/M+0 ratio at >1% D(3)-leucine incorporation. We calculated the FSR for each apolipoprotein by curve fitting the tracer incorporation data from each subject. RESULTS The LC-SRM method was linear over the range of tracer enrichment values tested and highly correlated with GC-MS (R(2) > 0.9). The FSRs determined from both methods were similar for HDL apoA-I and VLDL apoB100. We were able to apply the LC-SRM approach to determine the tracer enrichment of multiple proteins from a single sample as well as proteins isolated from plasma after immunoprecipitation. CONCLUSIONS The LC-SRM method provides a new technique for measuring the enrichment of proteins labeled with stable isotopes. LC-SRM is amenable to a multiplexed format to provide a relatively rapid and inexpensive means to measure turnover of multiple proteins simultaneously.
منابع مشابه
Gas chromatography tandem mass spectrometry offers advantages for urinary steroids analysis
Gas chromatography mass spectrometry has been the lynchpin of clinical assessment of steroid profiles for ∼3 decades. The improvements in assay performance offered by tandem mass spectrometry were assessed. Across the spectrum of glucocorticoid and androgen analytes tested, limits of detection and quantitation were ∼20 fold lower with triple than single quadrupole systems, but the more noticeab...
متن کاملMeasuring protein synthesis by mass isotopomer distribution analysis (MIDA).
The measurement of protein kinetics by isotopic techniques has been hindered by the long-standing difficulty of accurately measuring the isotope content of the biosynthetic precursor pool (aminoacyl-tRNA in tissues). Mass isotopomer distribution analysis (MIDA) is a stable isotope-mass spectrometric (MS) technique for measuring biosynthetic precursor enrichments from measurements on a polymeric...
متن کاملDevelopment and application of an analytical method using gas chromatography/triple quadrupole mass spectrometry for characterizing alkylated chrysenes in crude oil samples.
RATIONALE Recent advances in analytical techniques have led to the development of gas chromatography/triple quadrupole mass spectrometry methods that allow the identification of target analytes in complex environmental samples. We have employed this technology to develop a method for characterizing alkylated chrysenes, which are environmental toxins that are resistant to weathering. METHODS A...
متن کاملSimultaneous determination of iridoid glycosides, phenethylalcohol glycosides and furfural derivatives in Rehmanniae Radix by high performance liquid chromatography coupled with triple-quadrupole mass spectrometry.
In this study, a sensitive and selective method for simultaneously quantifying eight major components (four iridoid glycosides, three phenethylalcohol glycosides and one furfural derivative) of Rehmanniae Radix by high performance liquid chromatography coupled with triple-quadrupole mass spectrometry (HPLC-TQ-MS) was developed. The sample preparation was executed using an optimised ultrasonic m...
متن کاملAgilent 8800 Triple Quadrupole ICP-MS: Understanding oxygen reaction mode in ICP-MS/MS
The use of oxygen as a reaction gas for the removal of interferences in quadrupole ICP-MS is well established. However, prior to the development of the Agilent 8800 Triple Quadrupole ICP-MS (ICP-QQQ), the use of oxygen had been limited to determination of a small number of analytes in simple, well defined matrices. This is because oxygen can react with matrix components, analytes and polyatomic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 58 3 شماره
صفحات -
تاریخ انتشار 2012