Use of a dose-dependent follow-up protocol and mechanisms to reduce patients and staff radiation exposure in congenital and structural interventions.
نویسندگان
چکیده
BACKGROUND Increasingly complex structural/congenital cardiac interventions require efforts at reducing patient/staff radiation exposure. Standard follow-up protocols are often inadequate in detecting all patients that may have sustained radiation burns. METHODS Single-center retrospective chart review divided into four intervals. Phase 1 (07/07-06/08, 413 procedures (proc)): follow-up based on fluoroscopy time only; frame rate for digital acquisition (DA) 30 fps, and fluoroscopy (FL) 30 fps. Dose-based follow-up was used for phase 2-4. Phase 2 (07/08-08/09, 458 proc): DA: 30 fps, FL: 15 fps. Phase 3 (09/09-06/10, 350 proc): DA: 15-30 fps, FL: 15 fps, use of added radiation protection drape. Phase 4 (07/10-10/10, 89 proc): DA: 15-30 fps, FL: 15 fps, superior noise reduction filter (SNRF) with high-quality fluoro-record capabilities. RESULTS There was a significant reduction in the median cumulative air kerma between the four study periods (710 mGy vs. 566 mGy vs. 498 mGy vs. 241 mGy, P < 0.001), even though the overall fluoroscopy times remained very similar (25 min vs. 26 min vs. 26 min vs. 23 min, P = 0.957). There was a trend towards lower physician radiation exposure over the four study periods (137 mrem vs. 126 mrem vs. 108 mrem vs. 59 mrem, P = 0.15). Fifteen patients with radiation burns were identified during the study period. When changing to a dose-based follow-up protocol (phase 1 vs. phase 2), there was a significant increase in the incidence of detected radiation burns (0.5% vs. 2%, P = 0.04). CONCLUSIONS Dose-based follow-up protocols are superior in detecting radiation burns when compared to fluoroscopy time-based protocols. Frame rate reduction of fluoroscopy and cine acquisition and use of modified imaging equipment can achieve a significant reduction to patient/staff exposure.
منابع مشابه
Estimating the radiation dose of non-radiation workers from nuclear medicine patients
Introduction: As a valuable imaging modality, Nuclear Medicine (NM) indications is raising in clinical practice. The remained portion administrated radioactive material in patients’ tissues is a critical issue, especially when the procedure is performed in hospitalized patients, where the non-radiation workers present. The aim of this study was evaluation the dose of non-radia...
متن کاملDose estimation with the calibration of dose-response curve of micronucleus in human peripheral lymphocytes induced by 50MeV proton beams
Background: The purpose of this paper is to establish an easy and reliable biodosimeter protocol to evaluate the biological effects of proton beams. Materials and Methods: Human peripheral blood lymphocytes were irradiated using proton beams (LET: 34.6 keV μm−1), and the chromosome aberrations induced were analyzed using cytokinesis-blocked (CB) micronucleus (MN) assay. To determine th...
متن کاملOptimization of Head CT Protocol to Reduce the Absorbed Dose in Eye Lenses and Thyroid: A Phantom Study
Introduction: Utilization of computed tomography (CT) scans is increasing annually. This study aimed to reduce the absorbed dose of sensitive organs in the head (eye lenses and thyroid) and to assess changes in resultant images quality in head scans when the radiation dose is decreased. Material and Methods: An anthropomorphic phantom was examined with head protocols in both helical and sectio...
متن کاملEvaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry
Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...
متن کاملEvaluation of the annual effective dose to Cath Lab staff in the Afshar Hospital, Yazd and suggesting the radiation protection strategies to better management of occupational dose
Introduction Due to the increasing use of angiography procedures and the higher risk of deterministic and stochastic effects for radiation workers of these sections than other radiological procedures, radiation safety is very important in angiography staff. So, this study aimed to obtain the effective dose of angiography staff and compare them with the standard dose limit and finally outline th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
دوره 78 1 شماره
صفحات -
تاریخ انتشار 2011