Do less medialized reverse shoulder prostheses increase motion and reduce notching?

نویسندگان

  • Philippe Valenti
  • Philippe Sauzières
  • Denis Katz
  • Ibrahim Kalouche
  • Alexandre Sahin Kilinc
چکیده

BACKGROUND Cuff tear arthropathy is the primary indication for total reverse shoulder arthroplasty. In patients with pseudoparalytic shoulders secondary to irreparable rotator cuff tear, reverse shoulder arthroplasty allows restoration of active anterior elevation and painless shoulder. High rates of glenoid notching have also been reported. We designed a new reverse shoulder arthroplasty with a center of rotation more lateral than the Delta prosthesis to address this problem. QUESTIONS/PURPOSES Does reduced medialization of reverse shoulder arthroplasty improve shoulder motion, decrease glenoid notching, or increase the risk of glenoid loosening? PATIENTS AND METHODS We retrospectively reviewed 76 patients with 76 less medialized reverse shoulder prostheses implanted for pseudoparalytic shoulder with rotator cuff deficiency between October 2003 and May 2006. Shoulder motion, Constant-Murley score, and plain radiographs were analyzed. Minimum followup was 24 months (mean, 44 months; range, 24-60 months). RESULTS The absolute Constant-Murley score increased from 24 to 59, representing an increase of 35 points. The range of active anterior elevation increased by 61°, and the improvement in pain was 10 points. The gain in external rotation with elbow at the side was 15°, while external rotation with 90° abduction increased by 30°. Followup showed no glenoid notching and no glenoid loosening with these less medialized reverse prostheses. CONCLUSIONS Less medialization of reverse shoulder arthroplasty improves external and medial rotation, thus facilitating the activities of daily living of older patients. The absence of glenoid notching and glenoid loosening hopefully reflects longer prosthesis survival, but longer followup is necessary to confirm these preliminary observations. LEVEL OF EVIDENCE Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mid-term outcome of reverse shoulder prostheses in complex proximal humeral fractures.

The functional outcome of hemiarthroplasty in displaced proximal humeral 3- and 4-part fractures or fracture dislocations in elderly patients is frequently unpredictable and depends on the position of the prosthesis and tuberosity fixation. Reverse shoulder arthroplasty represents an alternative in elderly patients. The purpose of this study was to report the results of a retrospective series o...

متن کامل

Reverse shoulder arthroplasty: does reduced medialisation improve radiological and clinical results?

The purpose of this retrospective study was to assess the effect of the reduced medialisation of the Arrow reverse shoulder prosthesis on short-term clinical and radiological results. The clinical and radiological results of 47 Delta III reverse prostheses and 49 Arrow reverse prostheses were retrospectively compared at a minimum of twelve months follow-up. There was a significant increase (p <...

متن کامل

Late-Onset, Advanced Scapular Notching Associated with a Lateral Offset Reverse Arthroplasty Design - A Case Report

Reverse shoulder arthroplasty, introduced by Grammont et al. [1] in 1987, is commonly associated with scapular notching, [2] an impingement of the humeral cup against the scapula’s inferior border. Although the clinical significance of notching has been debated, 2 studies reported less successful clinical outcomes in its presence [2,3]. A laboratory study showed that a varus humeral neck-shaft ...

متن کامل

The Midterm Results of the Delta Xtend Reverse Shoulder System: A Five-Year Outcome Study

Background: The purpose of this study was to examine the mid-term functional outcomes, radiographic results,and revision rates of patients treated with the Delta Xtend Reverse Shoulder System for both primary and revisionarthroplasty indications.Methods: A retrospective review was conducted of records for all individuals who underwent a reverse shoulderarthroplasty using the Delta Xtend Reverse...

متن کامل

Six-year experience with the Delta III reverse shoulder prosthesis.

PURPOSE To report the clinical and radiographic results and complications of the Delta III reverse prosthesis. METHODS 24 women and 2 men aged 62 to 84 (mean, 75) years underwent total shoulder replacement using the Delta III reverse prosthesis. Patient diagnoses were massive rotator cuff tear (n=20), disabling sequelae of proximal humeral fractures (n=3), and failure of an unconstrained arth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 469 9  شماره 

صفحات  -

تاریخ انتشار 2011