In vivo and in vitro evaluation of the heparin management test versus the activated coagulation time for monitoring anticoagulation level in aprotinin-treated patients during cardiac surgery.

نویسندگان

  • Y S Kim
  • J M Murkin
  • S J Adams
چکیده

INTRODUCTION Monitoring whole blood anticoagulation therapy with the activated coagulation time (kaolin ACT) and the heparin management test (HMT) were correlated in vivo with the plasma anti-activated factor X (anti-Xa) heparin concentration in patients who received variable doses of aprotinin and in vitro in the presence of increasing concentrations of aprotinin. METHODS In 38 elective cardiac surgical patients who received an average heparin dose of 400 IU/kg and an average total aprotinin dose of 3.6 10(6) kallikrein-inhibiting units (KIU), ACT and HMT were measured in duplicate 6 times intraoperatively at predetermined intervals. Blood samples at each interval were also assayed for the anti-Xa plasma heparin concentration with the IL Test heparin chromogenic assay. The influence of increasing concentrations of aprotinin on HMT and ACT was also measured in vitro by using blood samples containing 6 IU/mL heparin from 6 additional patients after adding specific aliquots of aprotinin to achieve concentrations of 50, 100, 200, and 300 KIU/mL aprotinin. Linear regression analysis was used to compare HMT and ACT against anti-Xa. A P level <.05 was required for statistical significance. RESULTS Duplicate measurements were taken at all intervals, and HMT and ACT values were significantly correlated, both with each other (r = 0.86; P < .01) and with anti-Xa activity (HMT, r = 0.81 [P < .01]; ACT, r = 0.71 [P < .01]). Aprotinin prolonged both the kaolin ACT and the HMT time in a dose-dependent manner (P < .05), and its influence was significantly less in vivo on the HMT time than on the kaolin ACT (P < .001). CONCLUSIONS The abilities of the HMT and the kaolin ACT to measure anticoagulation effects were not significantly different. Aprotinin prolonged both the kaolin ACT and the HMT time in a dose-dependent manner, but the HMT was significantly less affected by aprotinin in vivo. The HMT is a reliable alternative to measuring the ACT in cardiac operations and may offer greater accuracy in aprotinin-treated patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Celite and Kaolin Based Heparin and Protamine Dosing Assays During Cardiac Surgery: The In Vitro Effect of Aprotinin

Both aprotinin and in vitro heparin and protamine dosing assays (RxDx System) have been shown to reduce postoperative bleeding in the cardiac surgery patient. While celite activated clotting time tests in the presence of heparin are artificially prolonged by aprotinin, the kaolin based ACT is not. In order to optimize heparin anticoagulation management during cardiac surgery when aprotinin is u...

متن کامل

بررسی وجود هپارین تزریق شده حین عمل جراحی عروق در خون بیماران قبل از خنثی کردن آن توسط

Heparine is a anticoagulation substance used in vascular surgery to prevent thrombosis during opration and after a while becomes neutralized by protamin an antiheparin drug. Protamine causes some dangerous complications including cardiovascular collapse, anaphilactoid reation, hypotention, bradycardia and bronchospasm. Using higher doses, also protamine leads to increase anticoagolation e...

متن کامل

Anti-coagulation therapy following coronary endarterectomy in patient with coronary artery bypass graft

Background: Since there is a lack of research on postoperative anticoagulation protocol in patients undergoing coronary artery bypass graft (CABG) / coronary endarterectomy (CE), we recommend a new protocol for anticoagulation in these patients. Methods: In this double-blind randomized clinical trial study, 52 patients undergoing CABG / CE entered the study and were divided into two groups. In...

متن کامل

Sensitivity of a modified ACT test to levels of bivalirudin used during cardiac surgery.

Assessment of anticoagulation status during cardiac surgery can be valuable for novel therapeutics, including direct thrombin inhibitors. The ecarin clotting time (ECT) has been reported to be sensitive for monitoring of bivalirudin in cardiac surgery but is not commercially available. The activated clotting time (ACT), commonly used for heparin monitoring, may display a lack of sensitivity to ...

متن کامل

Monitoring of Haemostasis and Anticoagulation in Cardiopulmonary Bypass Patients

Patients undergoing cardiac surgery with cardiopulmonary bypass are at risk of increased blood loss and transfusion requirements. Contact of blood with the surgical wound and the artificial surfaces of the extra-corporeal circuit results in a coagulopathy. Haemodilution during cardiopulmonary bypass also aggravates the reduction of haemostatic factors even further. On the other hand, systemic a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 2004