Does high-flexion total knee arthroplasty promote early loosening of the femoral component?
نویسندگان
چکیده
High-flexion knee replacements have been developed to accommodate a large range of motion (RoM > 120°). Knee implants that allow for higher flexion may be more sensitive to femoral loosening as the knee load is relatively high during deep knee flexion, which could result in an increased failure potential at the implant-cement interface of the femoral component. A 3D finite element knee model was developed including a posterior-stabilized high-flexion knee replacement to analyze the stress state at the femoral implant-cement interface during a full squatting movement (RoM ≤ 155°). During deep flexion (RoM > 120°), tensile and shear stress concentrations were found at the implant-cement interface beneath the proximal part of the anterior flange. Particularly, the shear stresses at this interface location increased during high flexion, from a peak stress of 4.03 MPa at 90° to 6.89 MPa at 140° of flexion. Tensile stresses were substantially lower, having a peak stress of 0.72 MPa at 100° of flexion. Using data from earlier interface strength experiments, none of the interface beneath the anterior flange was predicted to fail in the normal flexion range (RoM ≤ 120°), whereas the prediction increased to 2.2% of the interface during deeper knee flexion. Thigh-calf contact reduced the knee forces, interface load, and failure risk beyond 140-145° of flexion. Based on the more critical stresses at the femoral fixation site between 120° and 145° of flexion, we conclude that the femoral component has a higher risk of loosening at high-flexion angles.
منابع مشابه
Femoral component loosening in high-flexion total knee replacement: an in vitro comparison of high-flexion versus conventional designs.
High-flexion total knee replacement (TKR) designs have been introduced to improve flexion after TKR. Although the early results of such designs were promising, recent literature has raised concerns about the incidence of early loosening of the femoral component. We compared the minimum force required to cause femoral component loosening for six high-flexion and six conventional TKR designs in a...
متن کاملThe Effect of Sagittal Femoral Bowing on the Femoral Component Position in Total Knee Arthroplasty
Background: In the current study, we investigated that how sagittal femoral bowing can affect the sagittal alignment ofthe femoral component in total knee arthroplasty (TKA).Methods: There were 25 patients underwent TKA. Long leg radiography in lateral view was performed. The sagittalfemoral bowing (SFB) and component alignment in relation to the sagittal mechanical axis and distal anterior cor...
متن کاملDoes Kinematic Alignment and Flexion of a Femoral Component Designed for Mechanical Alignment Reduce the Proximal and Lateral Reach of the Trochlea?
BACKGROUND Kinematically aligned total knee arthroplasty uses a femoral component designed for mechanical alignment (MA) and sets the component in more internal, valgus, and flexion rotation than MA. It is unknown how much kinematic alignment (KA) and flexion of the femoral component reduce the proximal and lateral reach of the trochlea; two reductions that could increase the risk of abnormal p...
متن کاملHigh incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement.
We have examined the results obtained with 72 NexGen legacy posterior stabilised-flex fixed total knee replacements in 47 patients implanted by a single surgeon between March 2003 and September 2004. Aseptic loosening of the femoral component was found in 27 (38%) of the replacements at a mean follow-up of 32 months (30 to 48) and 15 knees (21%) required revision at a mean of 23 months (11 to 4...
متن کاملHybrid total knee arthroplasty: 10- to 16-year follow-up.
A cementless femoral component may allow for a smaller surgical incision when a minimally invasive approach is used during primary total knee arthroplasty. Fixation by cement is the gold standard for total knee arthroplasty. The results of cementless total knee arthroplasty are mixed. Cementless femoral components have done well. Although some tibial components have performed well at long-term ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic research : official publication of the Orthopaedic Research Society
دوره 29 7 شماره
صفحات -
تاریخ انتشار 2011