Subcoronary implantation or aortic root replacement for human tissue valves: sufficient data to prefer either technique?

نویسندگان

  • T P Willems
  • L A van Herwerden
  • E W Steyerberg
  • M A Taams
  • V E Kleyburg
  • R B Hokken
  • J R Roelandt
  • E Bos
چکیده

The aortic root replacement technique with aortic allograft or pulmonary autograft might be superior to the subcoronary allograft implantation technique with regard to aortic regurgitation. We explored the influence of the learning process on the incidence of reoperation and the severity of postoperative aortic regurgitation as assessed by color Doppler echocardiography. The subcoronary implantation technique was used in 81 patients, and root replacement was done in 63 patients. The first 30 patients of each group were considered as the surgeons' learning curve. Reoperations were more common in the subcoronary implantation group. After exclusion of early reoperations, the median regurgitation score based on echocardiographic examination was 0.22 in the first 30 patients from the subcoronary implantation group and 0.14 in the root replacement group. The subsequent patients from these groups had regurgitation scores of 0.20 and 0.17, respectively. Statistical analysis of these data showed no significant difference. This interim report suggests that the learning curve for the surgical procedure and the grouping of echocardiographic data influence the interpretation of follow-up studies. The superiority of either technique with regard to aortic regurgitation has yet to be proved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human tissue valves in aortic position: determinants of reoperation and valve regurgitation.

BACKGROUND Human tissue valves for aortic valve replacement have a limited durability that is influenced by interrelated determinants. Hierarchical linear modeling was used to analyze the relation between these determinants of durability and valve regurgitation measured by serial echocardiography. METHODS AND RESULTS In adult patients, 218 cryopreserved aortic allografts were implanted with t...

متن کامل

An alternative subcoronary implantation technique decreases the risk of complete heart block after stentless aortic valve replacement

CONTEXT Stentless aortic valve prostheses have excellent hemodynamic profiles, but may be associated with an increased postoperative heart block when compared to conventional prostheses. AIMS To assess the effect of an alternative subcoronary implantation technique on postoperative complete heart block (CHB) and permanent pacemaker implantation (PPI) following aortic valve replacement (AVR) w...

متن کامل

Stentless Aortic Valve/Root Replacement

In-vitro, stentless valves have a larger effective orifice area than their stented counterparts. This is best exemplified by the fact that a 25-mm Mosaic valve, which is stented, is manufactured using a 23-mm Freestyle stentless valve. So, in order to end-up with similar effective orifice areas when implanting a stentless valve or a stented valve in the same size left ventricular outflow tract,...

متن کامل

Ross procedure at the crossroads.

The quest for a perfect heart valve substitute has been going on for half a century. In 1960, Lower et al1 described the feasibility of replacing the aortic valve of dogs with the native pulmonary valve. In 1967, Ross performed this procedure in humans.2 Ross transferred the pulmonary valve into the aortic root with the same technique used to implant aortic valve homograft3 (ie, the pulmonary s...

متن کامل

Bioprosthetic valve durability after stentless aortic valve replacement: the effect of implantation technique.

BACKGROUND The Freestyle stentless bioprosthesis (FSB) (Medtronic Inc, Minneapolis, MN) is implanted using 2 techniques-subcoronary or aortic root replacement. Our objective was to determine whether the implantation technique had an impact on late reoperation for structural valve deterioration (SVD). METHODS Between 1993 and 2013, 531 patients underwent aortic valve replacement (AVR) or aorti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 60 2 Suppl  شماره 

صفحات  -

تاریخ انتشار 1995