Improving Depiction of Temporal Bone Anatomy With Low-Radiation Dose CT by an Integrated Circuit Detector in Pediatric Patients

نویسندگان

  • Jingzhen He
  • Yuliang Zu
  • Qing Wang
  • Xiangxing Ma
  • Thangamadhan Bosemani.
چکیده

The purpose of this study was to determine the performance of low-dose computed tomography (CT) scanning with integrated circuit (IC) detector in defining fine structures of temporal bone in children by comparing with the conventional detector. The study was performed with the approval of our institutional review board and the patients' anonymity was maintained. A total of 86 children<3 years of age underwent imaging of temporal bone with low-dose CT (80 kV/150 mAs) equipped with either IC detector or conventional discrete circuit (DC) detector. The image noise was measured for quantitative analysis. Thirty-five structures of temporal bone were further assessed and rated by 2 radiologists for qualitative analysis. κ Statistics were performed to determine the agreement reached between the 2 radiologists on each image. Mann-Whitney U test was used to determine the difference in image quality between the 2 detector systems. Objective analysis showed that the image noise was significantly lower (P<0.001) with the IC detector than with the DC detector. The κ values for qualitative assessment of the 35 fine anatomical structures revealed high interobserver agreement. The delineation for 30 of the 35 landmarks (86%) with the IC detector was superior to that with the conventional DC detector (P<0.05) although there were no differences in the delineation of the remaining 5 structures (P>0.05). The low-dose CT images acquired with the IC detector provide better depiction of fine osseous structures of temporal bone than that with the conventional DC detector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment

Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...

متن کامل

Medical imaging modalities: Prevention of unnecessary orders and non-optimized radiation exposure

Magnetic resonance imaging (MRI) uses a constant magnetic field and radio waves, a non-invasive method for examining tissues, organs and the skeletal system. Advantages and disadvantages of MRI are not fully understood; however, it has been commonly used in the diagnosis of skeleton and bone diseases (such as disk and spinal disorders, joint disorders (arthritis), bone tumours and tissues...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

Diagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates

Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...

متن کامل

Spiral CT of the temporal bone in unsedated pediatric patients.

PURPOSE To determine the feasibility of performing rapid, high-resolution, low-radiation-dose spiral CT scans of the temporal bone in unsedated pediatric patients. METHODS Axial spiral CT examinations with an effective section thickness of 1.25 mm were performed in 41 infants and children. Multiplanar reconstructions were generated using 360 degrees and 180 degrees linear interpolation algori...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 93  شماره 

صفحات  -

تاریخ انتشار 2014