Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty.
نویسندگان
چکیده
We measured the contact areas and contact stresses at the post-cam mechanism of a posterior-stabilised total knee arthroplasty when a posterior force of 500 N was applied to the Kirschner Performance, Scorpio Superflex, NexGen LPS Flex Fixed, and NexGen LPS Flex Mobile knee systems. Measurements were made at 90 degrees, 120 degrees, and 150 degrees of flexion both in neutral rotation and 10 degrees of internal rotation of the tibial component. Peak contact stresses at 90 degrees, 120 degrees, and 150 degrees were 24.0, 33.9, and 28.8 MPa, respectively, for the Kirschner; 26.0, 32.4, and 22.1 MPa, respectively, for the Scorpio; and 34.1, 31.5, and 32.5 MPa, respectively, for the NexGen LPS Flex Fixed. With an internally rotated tibia, the contact stress increased significantly with all the fixed-bearing arthroplasties but not with the NexGen LPS Flex Mobile arthroplasty. The post-cam design should be modified in order to provide a larger contact area whilst avoiding any impingement and edge loading.
منابع مشابه
Post impingement in posterior stabilised total knee arthroplasty.
Posterior stabilised implants are a well-proven treatment for patients requiring primary total knee arthroplasty. Concerns about the posterior stabilised (PS) design have been raised and recent studies suggest that the post-cam articulation can be an additional source of polyethylene wear debris. In this study, the authors report impingement of the tibial post against the patellar component in ...
متن کاملEarly results of posterior-stabilised NexGen Legacy total knee arthroplasty.
OBJECTIVE To retrospectively assess the early results of the NexGen Legacy posterior-stabilised total knee prosthesis, which is a newer version of the Insall-Burstein II posterior-stabilised implant. METHODS 48 consecutive elderly patients had 60 NexGen Legacy posterior-stabilised total knees. The mean follow-up duration was 21 months. Clinical evaluation was performed according to the Knee S...
متن کاملMechanics of post-cam engagement during simulated dynamic activity
Posterior-stabilized (PS) total knee arthroplasty (TKA) components employ a tibial post and femoral cam mechanism to guide anteroposterior knee motion in lieu of the posterior cruciate ligament. Some PS TKA patients report a clicking sensation when the post and cam engage, while severe wear and fracture of the post; we hypothesize that these complications are associated with excessive impact ve...
متن کاملHow effective are added constraints in improving TKR kinematics?
Newer designs of total knee arthroplasty (TKA), through the use of added degrees of constraint, attempt to provide a "guided motion" to restore more normal and predictable kinematics. Two such design philosophies are the posterior stabilised (PS) using a cam-post and the medial pivot (MP) concepts. Knee kinematics of 12 patients with a PS TKA, 13 subjects with a MP TKA and 10 normal subjects we...
متن کاملA kinematic comparison of fixed- and mobile-bearing knee replacements.
Mobile-bearing posterior-stabilised knee replacements have been developed as an alternative to the standard fixed- and mobile-bearing designs. However, little is known about the in vivo kinematics of this new group of implants. We investigated 31 patients who had undergone a total knee replacement with a similar prosthetic design but with three different options: fixed-bearing posterior cruciat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 87 4 شماره
صفحات -
تاریخ انتشار 2005