High-Throughput Micro-Debubblers for Bubble Removal with Sub-Microliter Dead Volume
نویسندگان
چکیده
We present the fabrication and evaluation of microdebubblers that are able to remove large bubbles while keeping a very low dead volume. The devices use a polytetrafluoroethylene membrane that is permeable to air in order to filter air bubbles out of an aqueous sample. The dead volume of the devices is less than one microliter, but bubbles as large as 60 microliters can be removed. This simple solution can be very useful for microfluidic devices for chemical or biological analysis that suffer from channel clogging due to the presence of bubbles in their sample. One embodiment is particularly suited for buffer solutions with living cells.
منابع مشابه
Formation of Hydrogen Peroxide by Chilled Goat Spermatozoa and the Effects of Dead Spermatozoa on Motility Characteristics
In this study, the formation of hydrogen peroxide (H2O2) by chilled goat spermatozoa was measured. Furthermore, the effects of dead spermatozoa on motility characteristics were studied. Fresh collected ejaculates from five Shami bucks were centrifuged and virtually all seminal plasma was removed. A part of the collected spermatozoa was killed by two ways: the first by repe...
متن کاملThe Effect of Micro Turbulence on Quartz Flotation Rate
In this research, the effect of micro turbulence on the flotation rate of quartz particles was investigated. The maximum particle Reynolds number (Rep) was obtained at 60.25 with a particle size of -500+420 µm, impeller speed of 900 rpm, bubble surface area flux of 10.21 1/s and micro scale turbulence size of 162 µm. When the micro turbulence size was equal to the particle size, ...
متن کاملApplication of New Inflection Point Method for Hydrodynamics Study in Slurry Bubble Column Reactors
Bubble column reactors are used in a wide variety of applications such as multiphase bioreactors, catalytic slurry reactors, and absorption processes. The superficial gas velocity-gas holdup relationship and transition point are two important parameters for characterizing the hydrodynamics of a bubble column reactor. In this study, systematic investigation of a nitrogen - water - glass bead...
متن کاملDesign, Optimization, and Test Methods for Micro-Electrode-Dot-Array Digital Microfluidic Biochips
Digital microfluidic biochips (DMFBs) are revolutionizing many biochemical analysis procedures, e.g., high-throughput DNA sequencing and point-of-care clinical diagnosis. However, today’s DMFBs suffer from several limitations: (1) constraints on droplet size and the inability to vary droplet volume in a fine-grained manner; (2) the lack of integrated sensors for real-time detection; (3) the nee...
متن کاملPharmaceutical Wastewater Chemical Oxygen Demand Reduction: Electro-Fenton, UV-enhanced Electro-Fenton and Activated Sludge
In this study, Chemical Oxygen Demand (COD) from a pharmaceutical wastewater (PhW) was reduced by several techniques such as electro-Fenton (EF), photo electro-Fenton (PEF) and activated sludge (AS) processes and the obtained data were compared with each other. The effects of several parameters such as pH, current density, H2O2/Fe2+ molar ratio, volume ratio of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Micromachines
دوره 3 شماره
صفحات -
تاریخ انتشار 2012