Light-scattering polarization measurements as a new parameter in flow cytometry.

نویسندگان

  • B G de Grooth
  • L W Terstappen
  • G J Puppels
  • J Greve
چکیده

Polarization measurement of orthogonal light scattering is introduced as a new optical parameter in flow cytometry. In the experimental setup, the electrical field of the incident laser beam is polarized in the direction of the sample flow. The intensity of the orthogonal light scattering polarized along the direction of the incoming laser beam is called depolarized orthogonal light scattering. Theoretical analysis shows that for small values of the detection aperture, the measured depolarization is caused by anisotropic cell structures and multiple scattering processes inside the cell. Measurements of the orthogonal depolarized light scattering in combination with the normal orthogonal light scattering of human leucocytes revealed two populations of granulocytes. By means of cell sorting it was shown that the granulocytes with a relatively high depolarization are eosinophilic granulocytes. Similar experiments with human lymphocytes revealed a minor subpopulation of yet-unidentified lymphocytes with a relative large orthogonal light-scattering depolarization. The results were obtained with an argon ion laser tuned at different wavelengths as well as with a 630-nm helium neon laser. These results show that measurement of depolarized orthogonal light scattering is a useful new parameter for flow-cytometric cell differentiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Simultaneous Determination of Size, Refractive Index, Light Scattering Depolarization and Fluorescence of Phytoplankton Cells by Laser Scanning Flow Cytometry

A new laser flow cytometer, based on a laser source of polarized light irradiating microscopic particles, has been developed. The unpolarized and linearly polarized scattered light, as well as the side emitted light in different spectral bands, are measured, allowing the simultaneous and realtime determination of size, refractive index, light scattering depolarization and fluorescence of each p...

متن کامل

Four-parameter white blood cell differential counting based on light scattering measurements.

Measurement of the depolarized orthogonal light scattering in flow cytometry enables one to discriminate human eosinophilic granulocytes from neutrophilic granulocytes. We use this method to perform a four-parameter differential white blood cell analysis. A simple flow cytometer was built equipped with a 5-mW helium neon laser that measures simultaneously four light scattering parameters. Lymph...

متن کامل

The first reported case of Aerococcus bacteremia in a patient with HIV infection.

6. Giacomini T, Lusina D, Foubard S, Baledent F, Guibert F, Le Pennec MP. Dangers of hematological automated analysis for malaria diagnosis. Bull Soc Pathol Exot 1991;84:330-3. 7. de Grooth BG, Terstappen LW, Puppels GJ, Greve J. Light-scattering polarization measurements as a new parameter in flow cytometry. Cytometry 1987;8:539-44. 8. Mendelow BV, Lyons C, Nhlangothi P, Tana M, Munster M, Wyp...

متن کامل

Towards Measurement of Polarization Properties of Skin using the Ellipsometry Technique

Introduction: The human skin is an active medium from the optical point of view. Therefore, the diagnostic and therapeutic techniques employing light are increasing. Current optical techniques are based on the measurement of the intensity of reflected absorbed or backscattered light from or within skin. Studies have shown that biological tissues, and in particular skin, demonstrate polarization...

متن کامل

Polarization of scatter and fluorescence signals in flow cytometry.

BACKGROUND The pulses of light scatter and fluorescence measured in flow cytometers exhibit varying degrees of polarization. Flow cytometers are heterogeneously sensitive to this polarization, depending on the light source(s), the optical layout, and the types of mirrors and filters used. Therefore, fluorescence polarization can affect apparent intensity ratios between particles and interfere w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cytometry

دوره 8 6  شماره 

صفحات  -

تاریخ انتشار 1987