Assessment of distraction callus in rabbits by monitoring of the electrical impedance of bone
نویسندگان
چکیده
BACKGROUND AND PURPOSE Evaluation of distraction callus is important for determination of the optimal time for removal of external fixation. We attempted to determine whether there might be a relationship between the electrical impedance of bone and callus maturation, with a view to using impedance as a way of knowing when to remove a fixator. METHODS We applied an external lengthener to the right tibia of 24 rabbits and performed distraction at 1 mm/day for 10 days. Radiographs were taken and measurement of overall impedance between fixation pins was performed weekly after distraction. At weeks 2, 4, 6, and 8 after distraction (n = 6 each), resistivity of the bone to electrical conductivity was measured before killing. Cross-sectional area of the conduction pathway in callus and maximum bending stress were measured after excision of the tibia. RESULTS The overall impedance increased statistically significantly from 1 to 6 weeks after completion of distraction. The resistivity of bone decreased over 4 weeks and the cross-sectional area of callus decreased significantly over 6 weeks, while the maximum bending stress increased significantly over the same time. We observed a negative correlation between the cross-sectional area of callus and maximum bending stress. INTERPRETATION The impedance values, which are related to changes in electrical conductivity and the conduction pathway, increased due to the changes in the cross-sectional area of callus, despite the reduction in bone resistivity. Since the cross-sectional area of callus was correlated with maximum bending stress and the impedance values increased with the callus-remodeling process, we suggest that temporal increases in overall impedance reflect callus maturation.
منابع مشابه
Assessment of Fracture and Distraction Callus by Monitering Bone Electrical Impedance in Rab- Bits
Introduction: Although external fixation is widely used for fractures and limb lengthening, evaluation of the time for removing the external fixator is dependent upon radiographic examinations and clinical findings, and a useful method has yet to be established clinically. Measurement of impedance is currently used in applications such as measuring body fat percentages and muscle volume of the ...
متن کاملParathyroid hormone PTH(1–34) increases the volume, mineral content, and mechanical properties of regenerated mineralizing tissue after distraction osteogenesis in rabbits
BACKGROUND AND PURPOSE Parathyroid hormone (PTH) has attracted considerable interest as a bone anabolic agent. Recently, it has been suggested that PTH can also enhance bone repair after fracture and distraction osteogenesis. We analyzed bone density and strength of the newly regenerated mineralized tissue after intermittent treatment with PTH in rabbits, which undergo Haversian bone remodeling...
متن کاملBone lengthening in rabbits by callus distraction. The role of periosteum and endosteum.
The histology and mechanics of leg lengthening by callus distraction were studied in 27 growing rabbits. Tibial diaphyses were subjected to subperiosteal osteotomy, held in a neutral position for 10 days and then slowly distracted at 0.25 mm/12 hours, using a dynamic external fixator. Radiographs showed that the gap became filled with callus having three distinct zones. Elongation appeared to o...
متن کاملChanges over time in callus formation caused by intermittently administering PTH in rabbit distraction osteogenesis models
BACKGROUND Changes over time in the callus during intermittent administration of parathyroid hormone (PTH) were studied in rabbit distraction osteogenesis models. METHOD Models of distraction osteogenesis in Japanese white rabbits were created, and distraction osteogenesis (total length: 10.5 mm) was performed for 2 weeks. Simultaneously with the start of distraction, 30 rabbits received 4 we...
متن کاملLow-intensity pulsed ultrasound accelerates bone maturation in distraction osteogenesis in rabbits.
We investigated the effects of low-intensity pulsed ultrasound on distraction osteogenesis in a rabbit model. Callotasis of the right tibia was performed in 70 male Japanese white rabbits using mini-external fixators. In the first part of the study in 64 animals using normal distraction (waiting period seven days; distraction rate 0.5 mm/12 hours; distraction period ten days), we evaluated the ...
متن کامل