Physics That May Be Realistic

نویسنده

  • George Kirakosyan
چکیده

The deadlock in physics is explained due to moral-epistemological aspects of basic principles and adopted methodology. A way out of crisis is suggested. It has shown that the long-term infertility of physical science is not due to technical difficulties (limited opportunities of mathematics, insufficient experimental means, etc.) as it is usually represented. However, the crisis in physics has arisen due to arbitrary, non-critical interpretation of key facts and with imposed speculative-artificial instructions. Building a harmonious and self-consistent physics becomes an implementable task with returning to cause-effect, conceptual representation of phenomena and to naturally analytical methodology

منابع مشابه

Evaluating the doismetric characteristics of some beta- emitter radionuclides for skin lesions irradiation

Introduction: The dosimetric characteristics of patch sources including 32P, 90Y, 188Re and 166Ho, which are employed for radionuclide skin therapy, have been evaluated in current study Materials and Methods: The patch sources understudy were modeled by MCNPX Monte Carlo code and corresponding depth dose distribution, transverse dose profile and isodose curves...

متن کامل

Impact of Input Pump Profile on the Gain Spectrum and the Saturation Behavior of One-Pump Fiber Optical Parametric Amplifiers

In this article, the impact of input pump profile on the gain spectrum as well as the saturation behavior of one-pump fiber optical parametric amplifiers (FOPAs) is investigated. Since in practical circumstances, pump sources used for FOPAs have Lorentz-Gaussian profile instead of Gaussian, a more realistic case is considered for simulating FOPAs in this article. The results of simulations for ...

متن کامل

Numerical Investigation of Angulation Effects in Stenosed Renal Arteries

Background: Numerical study of angulation effects of renal arteries on blood flow has been of great interest for many researchers.Objective: This paper aims at numerically determining the angulation effects of stenosed renal arteries on blood flow velocity and renal mass flow.Method: An anatomically realistic model of abdominal aorta and renal arteries is reconstructed from CT-scan images and u...

متن کامل

Effects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy

Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...

متن کامل

Monte Carlo investigation on precise dosimetry of HDR breast brachytherapy with Accuboost

Introduction: Accuboost is a HDR brachytherapy system in early stages breast cancer treatment. This device provides a completely noninvasive procedure with parallel-opposed radiation from two immobilizing peripheral applicators that caused it a preferred option of modalities to choose. In most commercial treatment planning systems, tissues are considered as a simple water phan...

متن کامل

Influence of Compensator Thickness and Field Size on Buildup factor of a Brass Compensator for Intensity- Modulated Radiation Therapy

Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015