Paramagnetic relaxation based biosensor for selective dopamine detection.

نویسندگان

  • Tevhide Ozkaya Ahmadov
  • Padmanabh Joshi
  • Jinnan Zhang
  • Keaton Nahan
  • Joseph A Caruso
  • Peng Zhang
چکیده

We report a new NMR relaxation time-based method for sensitive and selective dopamine detection using paramagnetic nanoparticles. The Fe(3+) species in the nanoparticles serves as both the contrast agent and the target recognition element. The results demonstrate that paramagnetic nanoparticles, similar to the more widely used superparamagnetic nanoparticles, can be integrated into relaxation based detection schemes while avoiding the aggregation problem commonly associated with superparamagnetic nanoparticles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tyrosinase-Based Biosensors for Selective Dopamine Detection

A novel tyrosinase-based biosensor was developed for the detection of dopamine (DA). For increased selectivity, gold electrodes were previously modified with cobalt (II)-porphyrin (CoP) film with electrocatalytic activity, to act both as an electrochemical mediator and an enzyme support, upon which the enzyme tyrosinase (Tyr) was cross-linked. Differential pulse voltammetry was used for electro...

متن کامل

Facile Synthesis and Electrochemical Performance of Graphene-Modified Cu2O Nanocomposite for Use in Enzyme-Free Glucose Biosensor

Graphene-modified Cu2O nanocomposite was synthesized under facile microwave irradiation of an aqueous solution and has been investigated as an enzyme-free glucose biosensor. Morphology and crystal structure of the graphene-modified Cu2O nanocomposite were investigated by using electron microscopy and X-Ray Diffraction (XRD) analyses. Also, the electrochemical performan...

متن کامل

A Micro-Platinum Wire Biosensor for Fast and Selective Detection of Alanine Aminotransferase

In this study, a miniaturized biosensor based on permselective polymer layers (overoxidized polypyrrole (Ppy) and Nafion(®)) modified and enzyme (glutamate oxidase (GlutOx)) immobilized micro-platinum wire electrode for the detection of alanine aminotransferase (ALT) was fabricated. The proposed ALT biosensor was measured electrochemically by constant potential amperometry at +0.7 V vs. Ag/AgCl...

متن کامل

Highly sensitive and selective uric acid biosensor based on direct electron transfer of hemoglobin-encapsulated chitosan-modified glassy carbon electrode.

A uric acid biosensor based on the direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode was developed for a highly sensitive and selective analysis in urine samples. The modified electrode was prepared by the encapsulation of hemoglobin and uricase in a chitosan matrix. The hydrogen peroxide produced from the catalytic oxidation of uric acid by uricase...

متن کامل

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical communications

دوره 51 57  شماره 

صفحات  -

تاریخ انتشار 2015