A new resorbable device for ligation of blood vessels - A pilot study

نویسندگان

  • Odd V Höglund
  • Ragnvi Hagman
  • Kerstin Olsson
  • Jonas Mindemark
  • Niklas Borg
  • Anne-Sofie Lagerstedt
چکیده

BACKGROUND During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency. METHODS The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs. RESULTS The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, n = 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, n = 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and vessel compression and occlusion were verified by histology. CONCLUSIONS Tests of functionality of the device showed complete haemostasis and good tissue grip. Devices with a band of sufficient length were easily applied and tightened in tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Resorbable Device for Ligation of Blood Vessels Development, Assessment of Surgical Procedures and Clinical Evaluation

Maintaining haemostasis during surgery is vital for a successful outcome. The objectives of this thesis were to develop a resorbable device, which would enable safe ligation and less surgical stress than the conventional method. For manufacturing of the device, the resorbable polymer polydioxanone was injection moulded. The device was constructed as a flexible band attached to a self-locking me...

متن کامل

Clinical, Histologic and Histomorphometric Evaluation of Bone Strip Allograft with Resorbable Membrane in Horizontal Alveolar Ridge Augmentation: A Preliminary Study

  Objective: Alveolar ridge preservation in patients with inadequate bone volume is one treatment option for successful implant placement and can be done by using bone graft materials. On the other hand, Ceno Bone has been recently produced by Hamanand Saz Baft Kish Co. as a bone bioimplant of allograft origin. This study aimed to assess the clinical, histologic and histomorphometric results of...

متن کامل

Mast Cell distribution and micro-anatomical location after bilateral uterine artery ligation in mature rabbits

To determine the effect of bilateral uterine artery ligation (BUAL) on mast cell (MC) distribution, 24 mature female rabbits were studied. The rabbits were ovariohysterectomized on day 23, 43 or 63 following BUAL. Histological sections were stained with toluidine blue to determine the MC distribution. In rabbits that had undergone BUAL, MCs were present extensively in the helium of the treated ...

متن کامل

Effects of sealing the perforated sinus membrane with a resorbable collagen membrane: a pilot study in humans.

The effects of repairing the perforated sinus membrane with collagen membrane are unknown. The purpose of this pilot study was to clinically, histologically, and histomorphometrically evaluate the results of repairing the perforated sinus membrane with resorbable collagen membrane. A split-mouth design was followed in the current study. Five subjects requiring bilateral sinus grafting were incl...

متن کامل

Menstrual Pattern following Tubal Ligation: A Historical Cohort Study

Background Tubal ligation (TL) is recommended for women who have completed their family planning. The existence of the menstrual disorders following this procedure has been the subject of debate for decades. This study was conducted to identify the relationship between tubal ligation and menstrual disorders. MaterialsAndMethods A historical cohort study was carried out on 140 women undergoing t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 53  شماره 

صفحات  -

تاریخ انتشار 2011