Real-time CT-guided percutaneous placement of LV pacing leads.
نویسندگان
چکیده
OBJECTIVES The aim of this study was to assess the feasibility of real-time computed tomographic (CT) imaging to guide the percutaneous placement of left ventricular (LV) leads in an animal model. BACKGROUND Cardiac resynchronization therapy has been shown to improve morbidity and mortality in patients with chronic heart failure. However, placement of the coronary sinus lead can be challenging and may require a more aggressive surgical approach. METHODS Nine swine were placed in a real-time CT scanner to define the safest percutaneous access strategy. Under real-time CT guidance, a 3.5-F pacing lead was placed percutaneously in the anterolateral LV epicardium (n = 6 swine) or to the posterolateral wall after the creation of intentional left pneumothorax (n = 3 swine) in a tangential (n = 12) or perpendicular (n = 1) approach. Pacing parameters and CT images were assessed during 30-min follow-up. Necropsy findings were compared with real-time CT images. RESULTS CT imaging successfully defined the safest percutaneous access route in all 13 lead placements and guided the therapeutic creation of pneumothoraces. Needle trajectory remained within 5 mm of the access route defined on CT imaging. LV lead placement under CT guidance was successful in all attempts within 19 ± 7 min. The mean pacing thresholds was 2.5 ± 1.5 V, the mean R wave amplitude was 11.2 ± 5.6 mV, and the mean impedance was 686 ± 103 Ω and remained unchanged after tangential placement during 30-min follow-up. Although no cardiac complications were observed with tangential lead placement (12 of 12), the perpendicular approach resulted in a pericardial effusion requiring pericardiocentesis. At necropsy, CT images correlated well with the in situ pathological results. CONCLUSIONS Percutaneous placement of LV pacing leads under CT guidance is feasible and might offer an alternative to more invasive surgical approaches in patients with complicated coronary sinus lead placement.
منابع مشابه
Application of Real-Time 3D Navigation System in CT-Guided Percutaneous Interventional Procedures: A Feasibility Study
Introduction To evaluate the accuracy of a quantitative 3D navigation system for CT-guided interventional procedures in a two-part study. Materials and Methods Twenty-two procedures were performed in abdominal and thoracic phantoms. Accuracies of the 3D anatomy map registration and navigation were evaluated. Time used for the navigated procedures was recorded. In the IRB approved clinical eva...
متن کاملInadvertent Lead Placement In The Left Ventricle: A Case Report And Brief Review
Inadvertent lead placement in the left ventricle (LV) is an uncommon and often under-diagnosed complication of cardiac device implantation. Thromboembolic (TE) events are common and usually secondary to fibrosis or thrombus formation on or around the lead. Anticoagulation can prevent TE events. Percutaneous and surgical LV lead extractions have been performed successfully, but the risks of perc...
متن کاملAcute and chronic performance evaluation of a novel epicardial pacing lead placed by percutaneous subxiphoid approach in a canine model.
BACKGROUND Endovascularly implanted leads risk vascular injury and endocarditis, and can be difficult to locate in desired positions for LV pacing. We evaluated the acute and long-term stability, electric performance and histopathology of a percutaneously placed intrapericardial lead (IPL). METHODS AND RESULTS Twelve adult mongrel dogs underwent defibrillator implants incorporating IPLs. Succ...
متن کاملOptimizing CRT - Do We Need More Leads and Delivery Methods.
Cardiac resynchronization therapy (CRT) is an established therapeutic option in symptomatic heart failure with reduced ejection fraction and evidence of left ventricular (LV) conduction delay (QRS width ≥120 ms), especially when typical left bundle branch block is present. The rationale behind CRT is restoration of aberrant LV electrical activation. As there is considerable heterogeneity of the...
متن کاملLung Lesions Biopsy in Children by Computed Tomography (CT) Fluoroscopy Guided Versus Conventional CT Scan Guided
Abstract Background Computed tomography (CT)-guided biopsy of the lung is a well-established method of diagnosis. The aim of this study was to determine the success rate of fluoroscopic CT (FCT) and conventional CT (CCT) in needle navigation biopsies from the lung lesions. Materials and Methods A total of 78 patients were prospectively enrolled to receive CT-guided biopsy with (group I, n=2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JACC. Cardiovascular imaging
دوره 6 1 شماره
صفحات -
تاریخ انتشار 2013