Coronary artery stent imaging with CT using an integrated electronics detector and iterative reconstructions: first in vitro experience.
نویسندگان
چکیده
BACKGROUND Despite continuous improvements in CT technology, accurate stent lumen delineation remains challenging. PURPOSE The aim was to evaluate the quality of coronary stent lumen delineation with CT using a detector with integrated electronics. METHODS Twelve coronary stents placed in plastic tubes and filled with contrast agent (CT number 250 HU) were imaged with either a 128-section dual-source CT machine equipped with conventional detector or with integrated electronics. On both scanners, images were reconstructed with filtered back projection (slice thickness 0.6 mm; increment 0.4 mm) and sinogram-affirmed iterative reconstruction (slice thickness 0.6 mm; increment 0.4 mm), and with iterative reconstruction (slice thickness 0.5 mm; increment 0.3 mm) on the integrated scanner. Two blinded, independent readers assessed image quality, noise, in-stent diameter, in-stent attenuation, and image sharpness by using signal intensity profiles across stents. RESULTS Interreader agreement for image quality assessment was substantial (κ = 0.798). Both readers rated best image quality in data sets from integrated detector at highest spatial resolution (86 or 72% of stents rated best quality). Image noise was significantly lower in data sets scanned with integrated detector, being lowest at 0.6 mm slice thickness (14.3 vs 21.0 HU; P < .001). Differences between measured and true in-stent diameters and differences in attenuation across stents were smallest, and average/maximum image sharpness was highest in data sets from the integrated detector using iterative reconstructions. CONCLUSION CT coronary stent imaging is significantly improved by using a detector with integrated electronics combined with iterative reconstructions.
منابع مشابه
Fast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملCoronary computed tomography angiography with 320-row detector and using the AIDR-3D: initial experience
Coronary computed tomography angiography (coronary CTA) is a powerful non-invasive imaging method to evaluate coronary artery disease. Nowadays, coronary CTA estimated effective radiation dose can be dramatically reduced using state-of-the-art scanners, such as 320-row detector CT (320-CT), without changing coronary CTA diagnostic accuracy. To optimize and further reduce the radiation dose, new...
متن کاملOptimal Stent Expansion by Stent Balloon Multiple Inflation at Nominal Pressure in Resistant Lesions: A New Technique
Introduction: This study aimed to evaluate the effects of four-time inflation of the stent balloon at nominal pressure on optimal stent expansion in resistant lesions. Materials and Methods: This interventional study was conducted on 39 patients with coronary artery lesions, in whom Zotarolimus-eluting stents (N=20), Paclitaxel-eluting stents (N=11) and other stents (N=8) were deployed four tim...
متن کاملCoronary artery stents: influence of adaptive statistical iterative reconstruction on image quality using 64-HDCT.
OBJECTIVE The assessment of coronary stents with present-generation 64-detector row computed tomography (HDCT) scanners is limited by image noise and blooming artefacts. We evaluated the performance of adaptive statistical iterative reconstruction (ASIR) for noise reduction in coronary stent imaging with HDCT. METHODS AND RESULTS In 50 stents of 28 patients (mean age 64 ± 10 years) undergoing...
متن کاملGiant aneurysm of the right sinus of Valsalva causing right ventricular outflow obstruction.
Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging 2010;26:591–7. 13. Tatsugami F, Husmann L, Herzog BA, Burkhard N, Valenta I, Gaemperli O et al. Evaluation of a body mass index-adapted protocol for low-dose 64-MDCT coronary angiography with prospective ECG triggeri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiovascular computed tomography
دوره 7 4 شماره
صفحات -
تاریخ انتشار 2013