In-use contamination of intravenous infusion fluid.
نویسندگان
چکیده
During the 1970 to 1971 nationwide epidemic of septicemias caused by Enterobacter cloacae and Enterobacter agglomerans traced to intrinsic contamination of Abbott intravenous infusion products, 94 infusion systems manufactured by Baxter Laboratories were studied microbiologically and epidemiologically during hospital use. Intravenous fluid from 10 systems (11%) contained microorganisms, usually Staphylococcus or Bacillus species; one infusion was heavily contaminated with Klebsiella pneumoniae. No national epidemic organisms, E. cloacae or E. agglomerans (formerly Erwinia), were recovered, suggesting that during this period frequent contamination with these organisms was unique to Abbott's infusion products. Contamination in this study appeared to be extrinsic in origin (introduced during clinical use) and related to the duration of continuous intravenous therapy. Nine of 61 systems (15%) that had been used longer than 48 h were contaminated, whereas only 1 of 33 used less than 48 h (3%) contained microorganisms. This study and the recent national outbreak indicate that contamination of infusion fluid, both from intrinsic and extrinsic sources, must be recognized as an additional risk of intravenous therapy; however, a once-daily replacement of the delivery apparatus can significantly diminish this hazard.
منابع مشابه
Isolation of interstitial fluid from skeletal muscle and subcutis in mice using a wick method.
Until recent years, mice were sparsely used in physiological experiments, and therefore, data on the basic cardiovascular parameters of mice are lacking. Our aim was to gain access to interstitial fluid and thereby study transcapillary fluid dynamics in this species. Using a modified wick method, we were able to isolate interstitial fluid from subcutis and skeletal muscle in mice. Three-strande...
متن کاملMeta-analysis of Inline Filtration Effects on Post-infusion Phlebitis Caused by Particulate Contamination of Intravenous Administration
− The particulate contamination of intravenously administered fluid has been of major concern. One of the most common complications associated with long term i.v. therapy is post-infusion phlebitis (PIP). We undertook a systematic review and meta-analysis of the effect of inline filters on PIP. An electronic search of Medline, KoreaMed, and KRIST was conducted to identify randomized controlled ...
متن کاملAccidental intravenous bolus infusion of potassium chloride in a young man with hypokalemic periodic paralysis
Hypokalemic periodic paralysis is anautosomal dominantdisease characterized by muscle weakness or paralysis with a matching fall in blood potassium levels. Paralysis attacks often occur in adolescence and are induced by strenuous exercise followed by rest, high carbohydrateor high sodiummeal content, sudden changes in temperature, and even excitement, noise, flashing lights and cold temperature...
متن کاملBacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran
There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...
متن کاملBacterial Contamination of Single- and Multiple-Dose Vials after Multiple Use and Intravenous Admixtures in Three Different Hospitals in Iran
There is possibility of microbial contamination of any single-dose vials (SDVs), multiple-dose vials (MDVs) and admixtures (ADXs) during the preparation and injection to the patients that could be resulted in bloodstream infection. The goal of this study was to investigate the microbial contamination of MDVs and SDVs after multiple use and ADXs prepared by nursing staff in the treatment room ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied microbiology
دوره 28 5 شماره
صفحات -
تاریخ انتشار 1974