Inter- and intra-observer variability in the echocardiographic evaluation of right ventricular function.

نویسندگان

  • Marta Pinedo
  • Eduardo Villacorta
  • Cristina Tapia
  • Roman Arnold
  • Javier López
  • Ana Revilla
  • Itziar Gómez
  • Enrique Fulquet
  • José A San Román
چکیده

INTRODUCTION AND OBJECTIVES Echocardiographic evaluation of right ventricular systolic function remains subject to debate because of the anatomic peculiarities of the right ventricle. Several methods have been developed for quantifying right ventricular systolic function. The aim of this study was to determine the reliability and reproducibility of a number of echocardiographic parameters by evaluating their inter-observer and intra-observer variability. METHODS The study included 30 patients with isolated mitral valvulopathy scheduled for heart surgery. All underwent echocardiography, which was performed independently by two echocardiographers within 24 hours. The intra-observer analysis was carried out using the recorded images at least 1 month after they had been obtained. The parameters studied were the tricuspid annular plane systolic excursion (TAPSE), the tricuspid annular peak systolic velocity on tissue Doppler imaging, right ventricular outflow tract fractional shortening, fractional shortening of right ventricular diameters, and fractional shortening of right ventricular areas. Variability was analyzed using the intraclass correlation coefficient. RESULTS The degree of concordance on TAPSE and tricuspid annular peak systolic velocity measurement was good in the inter-observer analysis and excellent in the intra-observer analysis. However, concordance was poor on measurements of the fractional shortening of the right ventricular outflow tract, areas and diameters on both inter-observer and intra-observer analyses. CONCLUSIONS The most reliable and reproducible echocardiographic parameters for evaluating right ventricular systolic function in patients with isolated mitral valvulopathy were the TAPSE and the tricuspid annular peak systolic velocity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Evaluation of Advanced Echocardiographic Parameters of Right Ventricular in Patients with Pulmonary Hypertension

Background and Objective: Pulmonary hypertension is an increase in blood pressure of the pulmonary artery which leads to right ventricular dysfunction. Therefore, the present study aimed to compare echocardiographic parameters in the study of right ventricular failure in patients with pulmonary hypertension. Materials and Methods: In the present descriptive cross-sectional study, data were col...

متن کامل

Comparison of Fetal Echocardiography for Fetal Cardiac Structure in Women with Gestational Diabetes Mellitus and Normal Pregnancies

BackgroundIncreased metabolic rate of hyperglycemia in gestational diabetes causes macrosomia, which can also affect the fetal heart. The thickness of the walls of the heart and its function in women with gestational diabetes mellitus (GDM) can change over time before treatment. We aimed to evaluate fetal cardiac structure in terms of ventricular wall thickness and its function in women w...

متن کامل

Echocardiographic assessment of right ventricular volumes: a comparison of different techniques in children after surgical repair of tetralogy of Fallot.

AIMS Different echocardiographic techniques are available for assessing right ventricular (RV) volumes but their clinical validity has not been well established. We compared the feasibility, reproducibility and accuracy of three different echocardiographic techniques for measuring RV volumes and ejection fraction (EF) in children after tetralogy of Fallot (TOF) repair. METHODS AND RESULTS Sev...

متن کامل

Reproducibility of myocardial velocity and deformation imaging in term and preterm infants.

AIMS Myocardial velocity imaging has been validated in adults for assessment of ventricular function and indirect indices of pulmonary arterial pressure. To establish whether it could also be used in infants, we investigated the reproducibility of myocardial velocities and deformation indices in term and preterm neonates. METHODS AND RESULTS Myocardial velocity loops acquired from 16 infants ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 63 7  شماره 

صفحات  -

تاریخ انتشار 2010