Determination and Levels of Chromium in French Wine and Grapes by Graphite Furnace Atomic Absorption Spectrometry

نویسندگان

  • Carmen Cabrera-Vique
  • Pierre-Louis Teissedre
  • Marie-Thérèse Cabanis
  • Jean-Claude Cabanis
چکیده

An accurate and precise method for direct determination of chromium in wine using graphite furnace atomic absorption spectrometry (GFAAS) is described. The method was also applied to grape samples treated by previous acid mineralization. A total of 79 wine samples from different regions in France and 12 grape samples of different varieties were analyzed. Chromium levels ranged from 7.0 to 90.0 μg/L in red wines, from 6.6 to 43.9 μg/L in white wines, from 7.3 to 14.7 in rosé wines, and from 10.5 to 36.0 μg/L in champagne. Deficient conditions in wine storage could increase chromium content. In grape samples, chromium content varied from 2.5 to 20.9 μg/kg for white varieties and from 2.4 to 64.6 μg/kg for red varieties. The contribution of wine consumption to total Cr daily dietary intake for the French population was estimated to be 4.06 μg per resident. The daily contribution of chromium from wine does not exceed 10% of dietary intake.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...

متن کامل

Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples

In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...

متن کامل

GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MAlIlRIX MODIFICATION FOR DETERMINATION OF LEAD IN DRINKING WATER

An amoniumvanadate plus sodium molybdate mixed modifier Graphite Furnace Atomic Absorption Spectrometric method has been developed for determination of traces of lead in drinking water. The concentration of lead in the sample is obtained by direct comparison to linear working graph prepared from aqueous standards in the modifier medium, The results indicate the better performance of the pro...

متن کامل

Determination of Chromium in Biological Material by Electrothermal Atomic Absorption Spectrometry Method

Procedure for determination of chromium in biological materials by Zeeman graphite furnace atomic absorption spectrometry method using a Perkin-Elmer spectrometer equipped with hollow-cathode lamp at 357.9 nm was developed. The samples of animal tissues, food, and feed were digested in muffle furnace at 450oC. The ash was dissolved in 1 N hydrochloric acid and the final solution was diluted in ...

متن کامل

International Union of Pure and Applied Chemistry Division of Chemistry and the Environment Commission on Oils, Fats and Derivatives * the Determination of Cadmium in Oils and Fats by Direct Graphite Furnace Atomic Absorption Spectrometry

A description is given of the development by collaborative study of a standardised method for the determination of cadmium in crude and refined oils and fats by graphite furnace atomic absorption spectrometry. The procedure is rapid and sensitive allowing determination at levels of 1–10 mg/kg

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997