Non Invasive Blood Glucometer

نویسندگان

  • Komal Lawand
  • Shital Patil
  • Mahesh Parihar
چکیده

Diabetes is a metabolic pathological condition of concern, which affects vital organs of body if not diagnosed and treated on time. Regular monitoring of blood glucose is important to avoid complication of diabetes. Commonly used glucose measurement methods are invasive which generally involves finger puncturing. These methods are painful and frequent pricking cause calluses on the skin and have risk of spreading infectious diseases. Therefore there is need to develop a non-invasive monitoring system which can measure blood glucose continuously without much problem. The present work is focused on development of non-invasive blood glucose measurement sensor system using Near-infrared (NIR) technique. In this study, near infrared optical measurement is applied to overcome the invasive issues. The designed device consists of an infrared emitter which placed over the fingertip for measurement of blood glucose optically. The near-infrared light will be sensed by the photo diode which having a certain wavelength. The intensity of received light is depending on the glucose molecules inside the blood. By analyzing the variation in voltages received after reflection in the cases the current diabetic condition as well as the approximate glucose level of the individual is going to be predicted. The obtained results are going to be validated with glucose meter readings and statistical analysis of the readings is to be done.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed Loop System on the Base of Non-Invasive Optical Glucometer

Closed loop system for diabetes mellitus compensation was developed. The system comprises a non-invasive optical glucose meter, an insulin infusion device and algorithm for blood glucose prediction. Glucometer consists of the control unit connected to the earlap clip by optical fiber. Experimental trials show that inherent accuracy of the optical system is 0.012 %, reproducibility – 0.06 %, RMS...

متن کامل

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

Alternate Glucometer Bio-sensor Model Based on Ultrasonic MEMS Transceivers

To prevent further complications in diabetes, proper management of blood glucose levels is essential. By using ultrasonic transceivers (both transmit and receive) the glucose level of human blood can be determined. Ultrasonic sensors works on the principle of generating high frequency sound waves by evaluating the echo which is received back by the sensor. By using this ultrasonic technique min...

متن کامل

Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article

This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...

متن کامل

Comparision between bed side testing of blood glucose by glucometer vs centralized testing in a tertiary care hospital.

BACKGROUND To determine the accuracy, turnaround time and cost effectiveness of bedside monitoring of blood glucose levels by non-laboratory health care workers and centralized testing of blood glucose by automated analyzer in a tertiary care hospital. METHODS The study was conducted in Section of Chemical Pathology, Department of Pathology and Microbiology and Section of Endocrinology Depart...

متن کامل

مقایسه میزان همخوانی یافته‌های سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد

Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014