BACKGROUND Since February 2002, Flextend electrode catheters are used at the Cardiovascular Unit of the Catholic University Clinical Hospital. These transvenous catheters have an IS-1 connector, silicone coating, active fixation and retractile helix with dexamethasone acetate. AIM To report early and one year results using Flextend catheters. MATERIAL AND METHODS Retrospective analysis of all patients that received an implant of a Flextend catheter in the Unit. RESULTS Forty one Flextend catheters were implanted in 24 patients, without acute displacement or clinical pericarditis. In 18 electrode catheters located in the right atrium the mean values for p wave, stimulation threshold and impedance at the moment of placement, were 2.9+/-1.4 mV, 0.8+/-0.4 V and 522+/-86 Ohms, respectively. The figures 24 hours after placement were 3.6+/-2.1 mV, 0.8+/-0.3 V and 612+/-69 Ohms, respectively. In 23 electrode catheters in the right ventricle, mean values at the moment of placement for R wave, stimulation threshold and impedance were 11.3+/-3.6 mV, 0.8+/-0.2 V and 756+/-108 Ohms, respectively. The figures 24 hours after placement were 3.6+/-2.1 mV, 0.8+/-0.3 V and 612+/-69 Ohms, respectively. In one patient, the stimulation threshold increased two months after placement and required a new intervention. CONCLUSIONS Flextend catheters ca be placed successfully with a low rate of complications and stable function parameters on follow up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flexible Electrode Array for Retinal Stimulation

In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...

متن کامل

Relationship of the P Angle with Stereotactic Arc in Intraoperative Outcome of Patients with Parkinson’s Disease Undergoing Deep Brain Stimulation

Background & Aim: DBS (deep brain stimulation) is a new and successful technique in treatment of symptoms of Parkinsonism especially after drug resistance. Research in this field is mostly designed for evolution of this technique. The present study aimed at evaluating the relationship between the angle formed in midsagittal and STN (sub-thalamic nucleus) axis line and recording l...

متن کامل

The Effects of Bilateral Subthalamic Nucleus Stimulation on Cognitive and Neuropsychiatric Functions in Parkinson’s Disease: A Case-Control Study

Introduction: Parkinson’s disease is one of the most disabling diseases which by electrode implantation and stimulation of subthalamic nucleus (STN), much progress has been made in the treatment of drug resistant patient. This new method of neurosurgery may have some neuropsychological side effects on the patients. The main aim of this study is to evaluate the effects of this kind of treatment ...

متن کامل

DESIGN AND STRUCTURE OF A NEW DEVICE FOR AUDITORY ELECTRICAL STIMULATION FOR SUPPRESSION OF TINNITUS

Auditory Electrical Stimulation for Tinnitus Suppression Tinnitus is the conscious experience of sound which arises in the head of its owner, but without a voluntary origin obvious to that person. About 10-15% of all adults report prolonged spontaneous tinnitus (PST). There are a lot of methods for suppressing this complaint. One of these methods is electrical stimulation. Electrical stimu...

متن کامل

Effect of Unilateral Transcranial Direct Current Stimulation on Reaction Time in Veterans and Disabled Athletes

Aims: Recently, Transcranial Direct Current Stimulation (tDCS) has been considered by researchers to improve various processes. The aim of this study was to investigate the effect of tDCS on reaction time in veterans and disabled athletes. Materials and Methods: This semi-experimental study with pre-test post-test design was conducted in 2018 among all veterans and disabled persons, who were me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista medica de Chile

دوره 134 6  شماره 

صفحات  -

تاریخ انتشار 2006